COMPLIANCE INFO_1989-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1777
>
2300 - Underground Storage Tank Program
>
PR0232397
>
COMPLIANCE INFO_1989-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/12/2023 2:46:38 PM
Creation date
6/3/2020 9:56:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1989-2005
RECORD_ID
PR0232397
PE
2361
FACILITY_ID
FA0003978
FACILITY_NAME
KAISER FOUNDATION - MANTECA
STREET_NUMBER
1777
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
20018034
CURRENT_STATUS
01
SITE_LOCATION
1777 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232397_1777 W YOSEMITE_1989-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORN14S WATER RESOURCES CONTROARD <br /> FORM `B': UNDERMTROUND STORAGE TANK PROAM <br /> rr TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. 10 <br /> f MARK QNLY w 1 NEW PERMIT ❑3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY C <br /> ONE ITEM ❑2 INTERIM PERMIT ❑4 AMENDED PERMIT [-]6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED <br /> 11751 wi. E Ylw w <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: ( eA FARM TANK-YES NO (� <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY <br /> A. OWNERS TANK ID It B. MANUFACTURED BY: U'W041zl <br /> 40" 161 <br /> i <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: 0,ewe), <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> I <br /> A. 5? 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. 1 UNLEADED ❑ 2 LEADED ®3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL ® 1 PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE El 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# ZA C.A.S.#: ��LA <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br />�{ <br /> A.TYPE OF i DOUBLE WALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> ❑ 1 STEEL/IRON ❑ 2 STAINLESS STEEL 3 FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE E]6 POLYVINYL CHLORIDE 7 ALUMINUM 8 100%METHANOL COMPATIBLE FAP <br /> MATERIAL <br /> ❑ 9 BRONZE 10 GALVANIZED STEEL ❑ 95 UNKNOWN 99 OTHER <br /> C. INTERIOR F-] 1 RUBBER LINED 2 ALKYD LINING 3 EPDXY LINING E] 4 PHENOLIC LINING <br /> LINING ❑ 5 GLASS LINING6 UNLINED E] 95 UNKNOWN <br /> ' <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ®'YES ❑ NO ❑99 OTHER <br /> D.CORROSION ❑ 1 POLYETHLENE WRAP ❑2 TAR OR ASPHALT ❑3 VINYL WRAP Nr4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABO%E GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE AU 1 SUCTION A V2 PRESSURE A 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED AU 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> 41 U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A we8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURETESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) nUBSTANCE;VtXG <br /> STIMATED QUANTITY OF 3. WAS TAN FILLED WITH <br /> IN INERTM T RIAL? ❑YES E] NO <br /> GALLONS N <br /> THIS FORM HAS BEEN COMPLETED UND R P LTY OF PERJURY,AND TO THE BEST OF MY KNOWLE GE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATUR DATE <br /> LOCAL AGENCY USE ONLY <br /> �! <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> 2` d <br /> CURRENT LOCAL AGENCY FACILITY ID# APPR m <br /> PHONE#WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE P MIT EXPIRATION DATE <br /> t <br /> r <br /> .CHECK# PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# BY: <br /> Am <br /> FORM a(s-2s-SS) THIS FORM MUST BE A COMPA BY A F LITYAM APPLICATION, FORM ` NLESS RE ORM'A' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.