ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2018
RECORD_ID
PR0232224
PE
2361
FACILITY_ID
FA0001877
FACILITY_NAME
AM PM HAMMER/I5 FOOD #83113
STREET_NUMBER
3250
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
08240009
CURRENT_STATUS
01
SITE_LOCATION
3250 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232224_3250 W HAMMER_2011-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
452
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FILL RISER CONTAINMENT SUMP TESTING <br />HEGEIVED <br />MAY 2 8 215 <br />Facility is Not Equipped With Fill Riser Containment Sumps e N <br />Fill Riser Containment Sumps are Present, but were Not Tested <br />Test Method Developed By: <br />❑ Sump Manufacturer ❑ Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: <br />❑ Pressure ❑ vacuum ❑ Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: <br />Equipment Resolution: <br />Fill Sump # <br />Fill Sump # <br />Fill Sump # <br />Fill Sump # <br />Sump Diameter: <br />Sump Depth: <br />Height from Tank Top to Top <br />of Highest Piping Penetration: <br />Height from Tank Top to <br />Lowest Electrical Penetration: <br />Condition of sump prior to <br />testing: <br />Portion of Sump Tested <br />Sump Material: <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />Test Start Time: <br />Initial Reading (R,): <br />Test End Time: <br />Final Reading (R,): <br />Test Duration: <br />Change in Reading (R, -R,): <br />Pass/Fail Threshold or Criteria: <br />Test Result: <br />El Pass El Fail <br />n Pass El <br />Fail <br />El Pass <br />fail <br />Pass El <br />Fail <br />Is there a sensor in the sump? <br />❑Yes ❑No <br />❑Yes ❑No <br />❑Yes ❑No <br />❑Yes ❑No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />❑Yes ❑No ❑N/A <br />❑Yes ❑No ❑N/A <br />❑Yes ❑No ❑N/A <br />❑Yes ,❑No [—]N/A <br />Was sensor removed for <br />testing? <br />❑Yes ❑No ❑N/A <br />❑Yes [—]No ❑N/A <br />❑Yes No N/A <br />❑Yes No ❑N/A <br />Was sensor properly replaced ❑Yes ❑No [—]N/A ❑Yes [—]No ❑N/A ❑Yes ❑No ❑N/A ❑Yes ❑No ❑N/A <br />and verified functional after <br />testing? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for ; <br />failed tests) <br />