COMPLIANCE INFO_2011-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3250
>
2300 - Underground Storage Tank Program
>
PR0232224
>
COMPLIANCE INFO_2011-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2021 10:16:11 AM
Creation date
6/3/2020 9:56:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2018
RECORD_ID
PR0232224
PE
2361
FACILITY_ID
FA0001877
FACILITY_NAME
AM PM HAMMER/I5 FOOD #83113
STREET_NUMBER
3250
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
08240009
CURRENT_STATUS
01
SITE_LOCATION
3250 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232224_3250 W HAMMER_2011-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
452
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• SAN JOAQUIN COUNTY • • <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd/unitiii.htmi <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility AM PM Hammer/15 Food Facility 3250 W. Hammer Ln. Stockton, CA Inspection Ma 1, 2012 <br />Name: Address: Date: y <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and Safety Code; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />Other Violations <br />999 Other: See attached "Continuation — Official Inspection Report' for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR -Notice to Comply) <br />On site to conduct a routine inspection and witness the annual monitoring system certification testing. <br />108. Secondary containment testing was last performed on 4-21-09 and was due before May 2012. <br />Testing has not been completed and is one month past due. Secondary containment testing is required <br />once every 36 months. Immediately schedule this test and provide 48 hours notification to the EHD. <br />113. A new designated operator, Edward Deyoung was hired on 8-29-11 and 9-20-11 and notification <br />was not provided to the EHD within 30 days of the change. Any changes shall be reported to the EHD <br />with 30 days. Submit notification to the EHD identifying all the designated operators for this facility by <br />6-1-12. <br />204. The designated operator failed to check and note the correct test dates for the secondary <br />containment test on the August 2011 through January 2012 designated operator monthly inspection <br />reports. The secondary containment test was listed as 4-2-09. It should have been listed as 4-21-09. <br />During the monthly inspection, the designated operator shall check that all required testing and <br />maintenance for the UST system have been completed and document the dates they were done. <br />Ensure that designated operators performing monthly inspections at this facility are including all of the <br />required information on the reports. , <br />205. The February 2012 designated operator monthly inspection report was not found on site. <br />Designated operator monthly inspection reports for the previous twelve months shall be retained on site. <br />Locate and ensure that copies of the previous twelve months of designated operator monthly inspection <br />reports are maintained on site. Submit copies to the EHD by 6-1-12. <br />305. The Bravo box float and chain in the sump failed to stop the flow of the 87 product at the #8 <br />dispenser when tested. All monitoring equipment shall be maintained to activate an audible and visual <br />alarm or stop the flow of product at the dispenser when it detects a leak. The service technician adjusted <br />the chain and verified functionality. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />k tA' <br />EHD 23-02 Rev 201/1C % \ Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.