Laserfiche WebLink
Mitoring System Certification <br />Site Address * 1777 W YOSEMITE AVE 6Date of Testing/Service: /03/2011 <br />D. Results of Testing/Servicing <br />Software Version Installed: na <br />Complete the following checklist: <br />* In Section E below, describe how and when these deficiences were or will be corrected. <br />E. Comments: <br />No setup ora arm history reports, because of the two monitors Perfiered Utilities and Owens Coming, neither have a printer. 205 day tank sensor <br />testedand tunctional <br />Page 2 of 3 Based on CA form dated 03/08 <br />No * <br />Is the audible alarm operational? <br />No * <br />Is the visual alarm operational? <br />r <br />No * <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />❑ No * <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not <br />interfere with their proper operation? <br />Yes <br />No * <br />ID N/A <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operational? <br />Yes <br />® No * <br />OX N/A <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive <br />shut -down? (check all that apply) ❑ Sump/Trench Sensors; ❑ Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? ❑ Yes No <br />® Yes <br />❑ No * <br />N/A <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e.: no mechanical <br />overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill points(s) and operating <br />properly? If so, at what percent of tank capacity does the alarm trigger? % <br />® Yes* <br />QX No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the <br />manufacturer name and model for all replacement parts in Section E, below. <br />Yes* <br />�x No <br />Was liquid found inside any secondary containment systems designed as dry systems? (check all that apply) ❑ Product; <br />❑ Water. If yes, describe causes in Section E, below. <br />®Yes <br />OX No * <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set-up reports, if applicable. <br />Q Yes <br />No * <br />Is all monitoring equipment operational per manufacturers' specifications? <br />* In Section E below, describe how and when these deficiences were or will be corrected. <br />E. Comments: <br />No setup ora arm history reports, because of the two monitors Perfiered Utilities and Owens Coming, neither have a printer. 205 day tank sensor <br />testedand tunctional <br />Page 2 of 3 Based on CA form dated 03/08 <br />