Laserfiche WebLink
RECEIVED <br /> Appendix VI (� <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.swl g.la. .� ,3 <br /> MONITORING SYSTEM CERTIFICATION ENVIRONMENTAL <br /> For Use By All Jurisdictions Within the State of California HEALTH DEPARTMENT <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Title 23, California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: KAISER MANTECA Bldg.No.: <br /> Site Address: 1777 W YOSEMITE AVE City: MANTECA Zip: 95337 <br /> Facility Contact Person: ENGINEERING MANAGER Contact Phone No.: 209-825-3460 <br /> Make/Model of Monitoring System: Other Manufacturer Owens corning Date of Testing/Servicing: 7/22/2013 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment ins ected serviced: <br /> Tank ID: T1-Diesel Tank ID: 2-Diesel <br /> In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: <br /> r' Annular Space or Vault Sensor. Model: Rs10-B r Annular Space or Vault Sensor. Model: <br /> r Piping Sump/Trench Sensor(s). Model: LS-3 Piping Sump/Trench Sensor(s). Model: Universal <br /> Fill Sump Sensor(s). Model: r,7 Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> r'.Tank Overfill/High-Level Sensor.Model: Flapper ,Tank Overfill/High-Level Sensor.Model: Universal <br /> I Other(specify equipment a and model in Section E on Pa e 2). Other(specify equipment a and model in Section E on Page 2). <br /> Tank ID: Tank ID: <br /> In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: <br /> r Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: r Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: r Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> r Electronic Line Leak Detector. Model: r Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor.Model: Tank Overfill/High-Level Sensor.Model: <br /> '« Other(specify equipment a and model in Section E on Pae 2). Other(Wecify a ui ment type and model in Section E on Pae 2). <br /> Dispenser Dispenser <br /> ID: ID: <br /> Dispenser Containment Sensor(s).Model: r Dispenser Containment Sensor(s).Model: <br /> Shear Valve(s). r Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser Dispenser <br /> ID: ID: <br /> Dispenser Containment Sensor(s).Model: r Dispenser Containment Sensor(s).Model: <br /> Shear Valve(s). r Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser Dispenser <br /> ID: ID: <br /> Dispenser Containment Sensor(s).Model: Dispenser Containment Sensor(s).Model: <br /> r Shear Valve(s). r Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply):r System set- <br /> up r,Alarm history report <br /> Technician Name(print): Brent Bowen Signature: PY <br /> Certification No.: 842815 License.No.: 743160 Class'A' <br /> Testing Company Name: Tanknology Phone No.: (800)800-4633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 Date of Testing/Servicing: 7/22/2013 <br /> Monitoring System Certification Page 1 of 3 12/07 <br />