My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1777
>
2300 - Underground Storage Tank Program
>
PR0232397
>
COMPLIANCE INFO_2009-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2023 1:49:50 PM
Creation date
6/3/2020 9:56:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2013
RECORD_ID
PR0232397
PE
2361
FACILITY_ID
FA0003978
FACILITY_NAME
KAISER FOUNDATION - MANTECA
STREET_NUMBER
1777
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
20018034
CURRENT_STATUS
01
SITE_LOCATION
1777 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\1777\PR0232397\PERMANENT INJUNCTION 05-11-11.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> San Joaquin County <br /> Environmental Health Department DIRECTOR <br /> ?•' ==,f—" <br /> . Donna Donna Heran, RENS <br /> z y 1868 East Hazelton Avenue <br /> Q' <br /> A. PROGRAM COORDINATORS <br /> Stockton, California 952056232 Robert McClellon,RENS <br /> .'. <br /> Jeff Carruesco,REHS,RDI <br /> q�iFo.R�� Website: wwwsjgov.org/ehd Kasey Foley,REHS <br /> Linda REHS <br /> Phone: (209)468-3420 Rodney Estrada,REHS <br /> Fax: (209)464-0138 Adrienne Ellsaesser,REHS <br /> October 9, 2013 <br /> Wayne Gathright COPYCal Phase Constriction, Inc. <br /> 1775 Monterey Rd., Ste. 60-A <br /> San Jose, CA 95112 <br /> Re: Kaiser Hospital, 1777 W Yosemite Ave, Manteca, CA SR0067724 <br /> The San Joaquin County Environmental Health Department (EHD) has reviewed the permit <br /> application to remove the underground piping tee of the generator/boiler F.O.R line, remove/or <br /> abandon in place.return piping associated with the above ground storage tank (AST),.repair the <br /> primary and the secondary piping where.the aforementioned tee was removed, modify piping at <br /> the sump on the underground storage tank (UST) system, and connect all the sensors to the <br /> existing TLS 350 Plus Veeder Root monitoring panel and recertify the system at the above <br /> referenced address. <br /> In order for this permit application review to continue, an addendum and revised sheets for the <br /> plans must be submitted for the following deficiencies: <br /> 1. Sheet number FO-G1, Cover Sheet, Site Plan, Notes & Maps, states "the pipe that <br /> .cannot be removed shall be triple rinsed and abandonfed] in place per the AHJ <br /> Instructions"' Since some piping may be abandoned in place, a Closure in Place permit <br /> needs to be submitted prior to mobilization on site. A copy of permit application is <br /> attached to this letter. Applicant shall also submit a written approval from the City or <br /> County Fire Prevention Bureau with jurisdiction allowing the Closure in Place (CIP) prior <br /> to the EHD permit approval. <br /> 2. Sheet number FO-G1, Cover Sheet, Site Plan, Notes & Maps, states "Remove the tee <br /> and as much of the associated pipe, that is associated with the generator day tank <br /> overflow, as possible." It is EHD's understanding that the proposed underground piping <br /> modification is to disconnect the return line leading from the boiler and not the one <br /> leading from the generator. Please provide clarification, and revise the above quoted <br /> statement to reflect the proposed scope of work, as appropriate, and submit a revised <br /> sheet number FO-G1 for EHD's review and approval. <br /> 3. Sheet number FO-M1.3, Modified Above Ground Fueling Piping Plan (F.O.S/F.O.R <br /> Connection), illustrates two supply lines ((E) F.O.C. from (E) US7) without a return line <br /> to the UST. Submit a'revised sheet number FO-M1 with the required information. <br />
The URL can be used to link to this page
Your browser does not support the video tag.