C <br />C <br />�J <br />11 � �M <br />PVC Insulation with Nylon Jacket <br />H 11 <br />jSolid or Stranded Soft -annealed Uncoated Copper <br />I <br />Applications <br />Type THHN/THWN conductors are primarily used in conduit for <br />services, feeder, and branch circuits in commercial or industrial <br />applications as specified in the National Electrical Cade®. <br />When used as type THHN or TWN75, conductor is suitable for use in <br />dry locations at temperatures not to exceed 90°C. <br />When used as type THWN or T90 Nylon, conductor is suitable for use <br />in wet or dry locations at temperatures not to exceed 75°C both dry <br />and wet locations or not to exceed 75°C when exposed to oil. <br />When used as type THWN-2, conductor is suitable for use in wet or <br />dry locations at temperatures not to exceed 90°C both dry and wet <br />locations or not to exceed 75°C when exposed to oil. <br />When used as type MTW, conductor is suitable for use in wet <br />locations or when exposed to oil at temperatures not to exceed 60°C <br />or dry locations at temperatures not to exceed 90°C (with ampacity <br />limited to that for 75°C conductors per NFPA 79). <br />Conductor temperatures not to exceed 105°C in dry locations when <br />rated AWM and used as appliance wiring material. Voltage rating for <br />all applications is 600 volts. <br />4, Specifications <br />Type THHN or THWN or MTW (also AWM) meets or exceeds all <br />applicable ASTM Specifications, UL Standard 83/CSA C22.2 <br />No. 75-03, UL Standard 1063 (MTW), UL Standard 758 (AWM), <br />Federal Specification A -A-59544, NEMA WC 70/ICEA S-95-658 and <br />the requirements of the National Electrical CodeO (NFPA 70). <br />4, Construction <br />Type THHN or THWN or MTW are copper conductors that are soft <br />annealed copper, insulated with a tough, heat and moisture resistant, <br />lead-free polyvinyl chloride (PVC) over which a nylon (polyamide) or <br />UL recognized equivalent jacket is applied. Available in black, white, <br />red, blue, green, yellow, brown, orange, purple, pink, or gray. Some <br />colors are standard, some subject to economic order quantity. <br />Conductor Insulation <br />Jacket <br />Nominal O.D. hit <br />Approximate <br />Allowable Ampacities + <br />Standard <br />Thickness Thickness <br />Net Weight <br />Package <br />hands) <br />(mils) <br />per 1000' (11o.) <br />SIZE AWG No. <br />or MCMI Strands <br />Solid Stranded <br />Solid Stranded <br />60°C <br />75°C <br />90°C <br />**14 19* 15 <br />4 <br />.102 .109 <br />15 16 <br />15 <br />15 <br />15 <br />AD' <br />**12 19* 15 <br />4 <br />.119 .128 <br />23 24 <br />20 <br />20 <br />20 <br />AD' <br />'*10 19* 20 <br />4 <br />.150 .161 <br />37 38 <br />30 <br />30 <br />30 <br />ADA <br />**8 19 30 <br />5 <br />.212 <br />63 <br />40 <br />50 <br />55 <br />BCDE <br />'*6 19 30 <br />5 <br />.250 <br />95 <br />55 <br />65 <br />75 <br />BCDE <br />419 40 <br />6 <br />.319 <br />153 <br />70 <br />85 <br />95 <br />BCDE <br />3 19 40 <br />6 <br />.346 <br />189 <br />85 <br />100 <br />110 <br />BCDE <br />2 19 40 <br />6 <br />.378 <br />234 <br />95 <br />115 <br />130 <br />BCDE <br />119 50 <br />7 <br />.435 <br />300 <br />110 <br />130 <br />150 <br />BCDE <br />1/0 19 50 <br />7 <br />.474 <br />372 <br />125 <br />150 <br />170 <br />BCDE <br />2/0 19 50 <br />7 <br />.518 <br />463 <br />145 <br />175 <br />195 <br />BCDE <br />3/0 19 50 <br />7 <br />.568 <br />576 <br />165 <br />200 <br />225 <br />BCDE <br />4/0 19 50 <br />7 <br />.624 <br />719 <br />195 <br />230 <br />260 <br />BCDE <br />250 37 60 <br />8 <br />.694 <br />849 <br />215 <br />255 <br />290 <br />BCG <br />300 37 60 <br />8 <br />.7471010 <br />240 <br />285 <br />320 <br />BCD <br />350 37 60 <br />8 <br />.797 <br />1175 <br />260 <br />310 <br />350 <br />BCD <br />400 37 60 <br />8 <br />.842 <br />1332 <br />280 <br />335 <br />380 <br />BCD <br />500 37 60 <br />8 <br />.925 <br />1652 <br />320 <br />380 <br />430 <br />BCD <br />600 61 70 <br />9 <br />1.024 <br />1990 <br />355 <br />420 <br />475 <br />BCE <br />750 61 70 <br />9 <br />1.126 <br />2468 <br />400 <br />475 <br />535 <br />BC <br />* Solid construction available in sizes 14, 12. <br />All AWG sites 14 AWG through 1 AWG rated VW I <br />STANDARD PACKAGING CODE: <br />& 10 as Types THHN or THWN or AWM <br />only. <br />All AWG sizes rated THWN <br />2 <br />" Also suitable for 105°C appliance wiring <br />Sizes 8 AWG and above rated Sunlight Resistant <br />A-500'Spool <br />E-5000'Reel <br />material(AWMI. <br />(blackcoloronly) <br />B-500'Reel <br />F-2000'Reel <br />°Four 500spools per carton. <br />Sizes 1/0 AWG and above <br />rated for Cable Tray Use <br />C - 1000' Reel <br />G - 4000' <br />Reel <br />A Two 500' spools per carton. <br />Sizes 1/0 AWG and above <br />rated FT4 / IEEE 1202 <br />D - 2500' Reel <br />+Allowable ampacities (see belowl- <br />Sizes 14 AWG and above Listed T90 Nylon or THWN <br />75 <br />Allowable ampacities shown are for general use as specified <br />by the National Electrical <br />Code, section 310-15. <br />60°C - When terminated to equipment for <br />circuits rated <br />100 amperes or less or marked <br />for AWG 14 through 1 conductors. <br />MTW wet locations or when exposed to oil <br />or coolant <br />75°C - When terminated to equipment for <br />circuits rated <br />100 amperes or marked for <br />conductors larger than 1 AWG. THWN <br />when exposed to oil or coolant. MTW dry locations. <br />907C - THHN dry locations. <br />6& Recommended Sample Specifications <br />(MTW or THHN or THWN or THWN-2) <br />Conductors shall be UL listed type MTW or THHN or THWN or THWN-2 gasoline <br />and oil resistant II for CT use (1/0 and larger), suitable for operations at 600 volts in <br />all installations as specified by the National Electrical Code@. Conductors shall be <br />annealed copper, insulated with high -heat, moisture resistant, and lead-free PVC, <br />jacketed with abrasion, moisture, gasoline, and oil resistant nylon or UL listed <br />equivalent. <br />(AWM) <br />Conductors shall be UL listed type THHN or THWN or THWN-2 or MTW or AWM <br />suitable for operation at 600 volts at conductor temperatures not to exceed 105°C. <br />