50' ' <br /> 0 1' 12' 0 1 ' 6 0 4 0 1 3 0 2 0 IF THIS SHEET IS NOT 30"x42", IT IS A <br /> 0 5' 0 5' 25 � � <br /> �� I _LLI _ 1iiiiiliiiii I I �.u�rliiiii I I i I i i i i i I � �_ i � � I i i �r REDUCED PRINT - SCALE ACCORDINGLY <br /> GRAPHIC SCALES: 1/16" = V-0" �8" 1/4" <br /> 1/2" = 1 '-0° 3/4" - V-0" „ = 1 '-0" 1-1/2" = V-0' 3" = V-0" <br /> ABSTRACT: The fuel oil system supports the emergency power generator system for the Kaiser Permanente Manteca Hospital <br /> Redundancies for the filtration pumps to the <br /> b <br /> UST fuel quality are required to ensure fail-safe operations Filter control operation for the emergency generator system will be managedy an INCON TS-550evo console. The <br /> - - for a completely automated system that supplies electronic information to the facilities �� � � RI��` ��A� N��E <br /> console will provide notification (local and remote) in the event of an alarm condition, p y y Kaiser Foundation Hospitals <br /> BMS (Building Management System) as well as notification to the fuel oil vendor, owners representatives, and local authorities if applicable. Facilities Design <br /> ( g g and Construction <br /> MANTECA MEDICAL CENTER <br /> will initial) consist of 1 filtration system with back up redundancy. However the necessary equipment will be able to run entire fuel oil system if ever desired. 1777 W. YOSEMITE <br /> The system y ( ) MANTECA, CA 95337 <br /> - filtration 248 <br /> Y nit <br /> FPC <br /> cure manufacturing filtratio <br /> nu <br /> Thus, the Incon controller will be outfitted with the appropriate quantity and type of modules needed to manage control of (1 ) Les g <br /> 204-0001 ). The filter system will have the capabilities to run the fuel system to (E) generator to day tank in a manual mode if needed. Revisions <br /> No. Revisions Cate <br /> 1 100% PERMIT SET 02/01/2017 <br /> Below are details of the hardware components, and the various operating modes and fueling scenarios. <br /> System consists of: <br /> I. FUEL OIL SYSTEM COMPONENTS <br /> 2. DAY TANK MANUAL CONTROL <br /> a. DESCRIPTION: Day tank fault condition has alarmed a LOW-LOW or HIGH-HIGH condition. <br /> 1. SUPPLY PIPING (QTY. 1) <br /> b. PURPOSE: Maintain fuel level in the day tank to keep the Generator in operation until issue has been <br /> resolved. <br /> 1. DESCRIPTION: Supply piping system. <br /> 2. PURPOSE: Deliver diesel fuel from the USTs to filtration. c. LOW-LOW CONDITION PROCEDURE: <br /> 3. DETAIL: The supply piping includes the following fuel handling components: 1. Operator must go to the corresponding day tank that alarmed and open the manual ball valve in the <br /> a. 1" OMEGA flex doubletrac piping and fittings. bypass loop. <br /> b. SCH 40 threaded steel epoxy coated pipe above ground. II. Operator to verify that Day Tank is in LOW-LOW condition and needs more product. <br /> c. Check valves 111. Operator shuts BV-1 and opens BV-2. <br /> d. Ball valves IV. Operator then monitors level in tank making sure that it does not overflow during this process <br /> watching the manual gauge located on the top of the day tank. <br /> 2. RETURN PIPING (QTY. 1) V. When day tank reaches 3/4 full operator should open BV-1 and close BV-2 to redirect product to UST <br /> as generator lowers Day Tank Level. If process of LOW LOW fuel happens again proceed to II. and <br /> 1. DESCRIPTION: Return piping system. <br /> repeat to V. until situation is corrected and function returns to normal operation. <br /> 2. PURPOSE: filtration and send back to the USTs. <br /> VI. Return system to normal operation after issue is resolved by pushing on screen button to"Stop Filter <br /> KEY PLAN: <br /> 3. DETAIL: The return piping includes the following fuel handling components: Pump"that was selected on and then opening BV-1 and closing BV-2 which is normal operating <br /> a. 1-1/2" OMEGA flex doubletrac piping and fitting. condition. If the level drops to a LOW LOW condition, the INCON controller will alarm again. f <br /> b. Check valve to control direction of fuel flow. <br /> c. Ball valve to isolate return piping from UST. <br /> TYPICAL MONTHLY SCHEDULE <br /> ,�. 3. FILTRATION SET(QTY. 1) SUNDAY MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY <br /> AREA OF WORK <br /> 1. DESCRIPTION: Self-contained cabinet providing 2 separate closed-loops for fuel filtration. The filtration set <br /> is supplied by a dedicated suction supply pipe. The filtered fuel is returned back to the supply piping in the <br /> 7AMTS1, the clean fuel circulates through the entire system returning back to the UST. The filtration can provide TURNOVERSTART SAM: <br /> TURNOVER DAY START PRIMARY UST <br /> fuel to the day tanks in the event both STPs fail. See P&ID for piping schematic TANKS FILTRATION <br /> 2. PURPOSE: Filter out contaminants from fuel system. <br /> 3. DETAIL: The filtration set includes the following fuel handling components: j <br /> a. (2) Haight 30 GPM positive displacement pump with built-in pressure relief bypass to circulate fuel from <br /> IAM START 7AM: <br /> the UST with (2) Leeson 1.SHP single phase 208VAC pump motor , activated by the INCON TS-550evo TURNOVER DAY !,START PRIMARY UST <br /> CONTROLLER. TANKS` !FILTRATION <br /> b. (2) Bucket strainer for a pump pre-filter. <br /> I <br /> c. (4 HYDRAULIC FLEX HOSE for pump <br /> vibration isolation. <br /> d. (2) SIGHT GLASS series flow indicator for visual inspection. 7AM:1TART <br /> 7AM. <br /> *RANDOM AIR <br /> TURNOVER DAY START PRIMARY UST QUALITY GENERATOR <br /> e. (2) RCI Fuel Purifier. TANKS FILTRATION RUN TEST OSHPD REVIEW <br /> 4. OPERATION: The UST will be filtered via a scheduled event initiated by the INCON CONTROLLER to filter <br /> j the fuel in the UST for 5 hours every other week. Water accumulated in water separator will be monitored by <br /> operator and manually drained by opening the ball valve located at the bottom of the fuel purifier. C HPD n/C <br /> 5. REDUNDANCY: The filtration units can be used to pressurize the supply piping in the event that the DAY 17AM:SIART 7AM V V V E D <br /> .,TURNOVER DAY !START PRIMARY UST �� <br /> sequence of operation section below for subsequent fueling scenarios in the event the !FILTRATION Office of Statewide Health <br /> TANK PUMPS. See se u p (TANKS. � Planning and Development <br /> � q 9 <br /> `I <br /> filtration pumps FOR THE DAY TANK PUMPS I , <br /> II <br /> Div. of Facilities Development <br /> Si9 nature: Date: <br /> 4. INCON CONTROLLER (QTY. 1) <br /> 7AM S <br /> TART <br /> 7AM: <br /> 1. DESCRIPTION: Incon TS-550evo Fuel Management System console TURNOVER DAY START PRIMARY UST <br /> TANKS FILTRATION This document is the property of the Owner and is <br /> 2. PURPOSE: Incon controller, serves as a fully-integrated fuel system controller and leak detection monitor. <br /> not to be used without his written permission <br /> Managing fuel filtration. Monitor sensors to provide local and remote alarm notifications. If required. <br /> 3. DETAIL: The Incon controller continuously monitor all day tank system outputs, and control fuel system Project Architect Approval: <br /> outputs to orchestrate overall standby generator fuel supply, leak detection, inventory management, and <br /> filtration cycles. Continuously monitors sensors. INCON controller consists of: UST-1 PRIMARY UST-2 PRIMARY <br /> Architect Engineer Of Record: <br /> a. (1) Incon TS-550evo console, including (11) module slots, built-in Power Supply Module, Controller <br /> Engineer Of Record: <br /> Module, Ethernet, serial ports, USB port, RS-485 port, and CAN bus. <br /> b. (1) 12-input AC input module for STP activate request detection 'NOTE: FACILITY TO PERFORM RANDOM AIR QUALITY GENERATOR RUN TEST ONCE A MONTH. LESCURE WILL RECEIVE NOTIFICATION of EMERGENCY FUEL <br /> T <br /> THROUGH INCON WEB BASED MONITORING SYSTEM. A RANDOM GENERATOR RUN WOULD BE A GOOD TEST AND CONFIRMATION OF THE FUEL OIL SYSTEM ev1l.D C0/VT <br /> c. (1) 8-input, 4-output 1/0 modules; total capacity of (48) inputs of 3-240V AC or DC, and (24) outputs PROPER FUNCTION. ���P� F K9T <br /> interfaced to: S�mo� RE EIV <br /> d. (3) 8-channel, 2AMP relay modules; total capacity of(48)outputs interfaced to: <br /> * Lic.# 248204 * FEB 0 6 2017 <br /> 1. (2) Filtration pump contactors <br /> C�S�RE C M�N�1 <br /> if. (3)AC input module run detect feeds ENVIRONMENTAL HEAL?E <br /> DEPARTMENT <br /> iii. (1) Remote annunciator(w acknowledgement switch) <br /> e. (1) 12-channel two-wire sensor modules; total capacity of(36)sensors, interfaced to: LESCURE <br /> ii. (9)TSP-ULS universal liquid sump sensors for: <br /> 5. (1) Filtration cabinets <br /> y COMPANY , INC <br /> GENERAL CONSTRUCTION SERVICES <br /> 5. OPERATION: SEE NEXT SECTION PLI 1nAgING EQUIPMENT SCHEDULE GENERAL ENGINEERINGSERVICES <br /> V I V I 2301 Arnold Industrial Way,Ste C,Concord Ca. <br /> Office(925)283-2528 Fax(925)283-1630 <br /> MOTOR RATED TANK CAPACITY MANUFACTURER REMARKS <br /> CODE AREA DESCRIPTION GPM HEAD <br /> It SEQUENCES OF OPERATION (Examples that follow assume GENERATOR 1) LOCATION HP RPM V PH (GALLONS) MODEL NUMBER <br /> & <br /> Facility <br /> MANTECA MEDICAL CENTER <br /> UST FILTRATION SCHEDULING FUEL OIL SYSTEM N/A SIMPLEX OR EQUAL 1777 W. YOSEMITE <br /> 1. <br /> a. DESCRIPTION: Filter fuel in PRIMARY UST FPC EQMEC PACKAGED PUMP SET (2)@7 20 �2 800 5 SPS-20 <br /> MANTECA, CA 95337 <br /> 1 <br /> b. PURPOSE: Maintain fuel purity on ongoing basis. <br /> Project <br /> c. DETAIL: During normal operation, the FILTRATION SET assigned to the UST should run fora 5-hour <br /> period within that UST's active week. PROVIDE WITH FUEL STRAINERS, CHECK VALVE, MANUAL SHUT-OFF VALVE, PRESSURE RELIEF VALVE, LEAK KAISER MANTECA <br /> I. When DATE/TIME of SCHEDULED TURNOVER DETECTION ALARM FOR CONTAINMENT(LS1 , SEE E1 . 1 ), DOOR MOUNTED DISCONNECT SWITCH WITH INTERLOCK UST FUEL FILTER SYSTEM <br /> i. INCONCONTROLLERwiIlcloseNOoutputRELAYCHANNEL#FLTR1 (fedbycontinuous110VAC PUMP RUNNING AMBER LIGHT, AUTOMATIC DUPLEX PUMP CONTROLLER, SINGLE PHASE STARTER, 7 GPM <br /> G1: from supply breaker), routing power to coil of FILTER PUMPCONTACTOR1. HIGHUFT PUMP, WEATHER PROOF MODIFICATION. <br /> Ili. FILTER PUMP CONTACTOR1 energizes, routing 120VACto FILTERPUMP1 and runs O PROVIDE WITH SECONDARY CONTAINMENT CLOSED TOP, SRS ANALOG CONTROLLER WITH FLOAT SWITCHES, Sheet Title \I [� /� \' �" C <br /> continuously until end of scheduled period. POWER AVAILABLE GREEN PILOT LIGHT, PUMP RUN/OFF/AUTOMATIC, LOCAL�REMOTE LOW FUEL LEVEL ALARM GENERALNOTES <br /> 1 E.V <br /> iv. Product flows from thededicated1"fueloilSUPPLYPIPEthroughFILTERCABINET, then WITH LIGHT, LOCAL/REMOVE HIGHT FUEL LEVEL ALARM WITH LIGHT, VENT CAP 2" NPT, EMERGENCY VENT CAP & EQUIPMENT SCHEDULE <br /> discharges back to UST THROUGH SUPPLY PIPE and looping through the RETURN PIPE. 4"NPT, MANUAL SHUTOFF VALVE 1 " BRONZE, TANK INLET SUPPLY DROP TUBE 1 "NPT, FLOAT SWITCH IN <br /> v. INCONsendsemailconfirmationtoOPERATORthatFILTRATIONCYCLEhasbegun. CONTAINMENT VV/ALARM(LS2-4, SEE E1 . 1 ). <br /> Fac No: - Bldg No: --- Floor Lev: Section: <br /> vi. When 5 hours have passed, INCON CONTROLLER open RELAY CHANNEL FLTR1, removing Scale SCALE PA No. as-27700 <br /> power to FILTER PUMP CONTACTOR1, which de-energizes FILTER PUMP1. <br /> Drawn By TRB <br /> Permit No. - <br /> Sheet <br /> vii. INCON sends email confirmation to OPERATOR that FILTRATION CYCLE has ended. <br /> Chckd By BB <br /> Issue Date 0210112017 <br /> G0 , 01 <br />