Laserfiche WebLink
IF <br /> DE <br /> e IF <br /> UNIDERGROUNp STORA1 1dGE TANK: ©J . <br /> ;SECONDARY CONTAINMENT .TESTING REPORT FORK) (Page 1 of`6) . , <br /> Type of Action ❑ installation Test ® Repair Test ❑ Six Month Test ❑ 36 Month Test <br /> 1 111, <br /> 1; FACILITY INFORMATION <br /> CERS ID Date of Secondary Containment Test <br /> 10181559 112/6/2018 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> Kaiser Manteca Medical Center <br /> Business Site Address City ZIP Code <br /> 1777 W. Yosimite Avenue I Manteca 95337 <br /> . II 1 . 1. UN RGROUND STORAGE TANK SERVICE TECHF 9 NIC, IAN ;INFOR <br /> MAT9. <br /> ION '. . 91 F <br /> Name of UST Service Technician Performing the Test (Print as shown on the ICC Certification) Phone # <br /> Saul Gonzalez I 949460-5200 <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 808313 Class A 5254881 <br /> 111, SUMMARY OF 4 4SECONDARY CONTAINMENIF T:?ESTING,:RESULTS <br /> TANK ID: (By tank number, stored product, etc,) A Diesel B C D <br /> IF IF t4 , <br /> Tank Containment EFILF = _ _ <br /> IF <br /> IF <br /> �� <br /> Tightness Test Result ❑ Pass ❑ Fall [INA ❑ Pass ❑ Fail ❑ NA [] Pass ❑IFail [INA �❑�Pass Ll Fail ❑ NA <br /> Product Piping Containment 3E - IF <br /> P g Cit " m F _ _ <br /> Tightness Test Result ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass [] Fall ❑ NA ❑ Pass ❑ sFall ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail [INA ❑ Pass ❑ Fail [INA ❑ Pass ❑ Fall [INA ❑ Pass ❑ Fail ❑ NA <br /> µ ' = <br /> Remote FIII Piping Containment _ <br /> Tightness Test Result F ❑ Pass ❑ Fall ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass (❑ Fall ❑ NA ❑Pass ❑ Fail 0 NA <br /> Communication Test Result ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> ` <br /> 111,,1--c=am - s - FFF1 s . ' - c' =" ' _:. <br /> Vent Piping Containment = . <br /> Tightness Test Result ❑ Pass [:] Fall ❑ NA ❑ Pass ❑ Fail [INA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA [I Pass ❑ Fall ❑ NA <br /> 4 <br /> IF <br /> Vapor Recovery Piping Containment y" _ x r " _`FFIz � IF <br /> z <br /> Tightness Test Result [] Pass E] Fall ❑ NA [IPass ❑ Fall [INA ❑ Pass Q] Fail ❑ NA ❑Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail [INA ❑ Pass [] Fail ❑ NA ❑ Pass ❑ Fall ❑ NA <br /> Turbine / Product Piping Sump ==IN z _ffl � <br /> Tightness Test Result M Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass [] Fall ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Fill Riser Sump <br /> ONE <br /> Tightness Test Result [] Pass ❑ Faii ❑ NA [I Pass ❑ Fail ❑ NA ❑ Pass d] Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> i <br /> VENT I TRANSITION SUMP ID: a b C d <br /> FF <br /> Tightness Test Result [:] Pass ❑ Fail ❑ NA ❑ Pass [I Fail ❑ NA ❑ Pass E] Fall ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> UDC ID : 1 2 3 4 <br /> Tightness Test Result [] Pass ❑ Fail ❑ NA ❑ Pass ❑ Fall [INA ❑ Pass ❑ Fall ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> i <br /> uoc ID : 5 6 7 8 <br /> Tightness Test Result ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ FailIONA <br /> ❑ Pass (:] Fail ❑ NA ❑ Pass ❑ Fail [INA <br /> UDC ID : 9 10 11 12 <br /> Tightness Test Result ❑ Pass ❑ Fall ❑ NA ❑ Pass [I Fall ❑ Pass ❑ Fail [INA ❑ Pass ❑ Fail ❑ NA <br /> All Items marked "Fall" or "NA " must be explained In their respective "COMMENTS" section. <br /> IV <br /> : CERTIFICATION SYUSTSSRVIGE TECHNICIAN :CONDUCTING THIS . TESTING <br /> I hereby certify that the secondary containment was tested In accordance with California Code of Regulations, Title 23, Division <br /> 3, Chapter 16, Section 2637 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = International Code Council, NA = Not Applicable, UDC = Under- <br /> Dispenser Containment <br />