My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3434
>
2300 - Underground Storage Tank Program
>
PR0232398
>
COMPLIANCE INFO_2004-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 10:56:57 AM
Creation date
6/3/2020 9:57:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2015
RECORD_ID
PR0232398
PE
2361
FACILITY_ID
FA0003681
FACILITY_NAME
STOCKTON AUTO CENTER CAR WASH
STREET_NUMBER
3434
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12802011
CURRENT_STATUS
01
SITE_LOCATION
3434 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232398_3434 E HAMMER_2004-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
579
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i • C0 <br /> �" '✓ UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 1 <br /> (Two pages per tank) <br /> 19 11 <br /> Page_of <br /> TYPE OF ACTION MI.NEW PERMIT ❑ 4.AMENDED PERMIT ❑ 5.CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK CLOSURE 430. <br /> (Check one item only) 3.RENEWAL PERMIT ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (Specify reason) (Specify reason) ❑ 8.TANK REMOVED <br /> BUSINESS NAME(Sam asFACILITY NAME orDBA-Doing Business As) 3. FACILITY ID: w 1C> <br /> l <br /> mat> i.1 I.IT Ccru c vA`3 1� <br /> LOCATION WITHIN SITE(optional) L^n ^L 3 431. <br /> I.TANK DESCRIPTION S <br /> (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID#T/QS/S 7.?_3432- JJK MANUFACPJRER 433. COMPARTMENTALIZED TANK [:]Yes Imo 434. <br /> T4a. L ')tAt-F' If"Yes,"complete one page for each compartment. <br /> DATE INSTALLED 435. TANK CAPACITY IN GALLONS 436- NUMBER OF COMPARTMENTS 437. <br /> (YEAR/MO� <br /> dgq >� <br /> ADDITIONAL DES RIPTION(For local use only) 438. <br /> IL TANK CONTENTS <br /> TANK USE 439• PETROLEUM TYPE 440. <br /> 93-1. MOTOR VEHICLE FUEL 21a, REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (Ifchecked,complete Petroleum Type) ❑Ib. PREMIUM UNLEADED ❑3. DIESEL [16. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM ❑Ic. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials Inventory page) 441. CAS#(from Hazardous Materials Inventory page) 442. <br /> ❑ 4. HAZARDOUS WASTE <br /> (Includes Used Oil) <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑1. SINGLE WALL ❑3. SINGLE WALL WITH EXTERIOR ❑5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br /> (Check one item only) MEMBRANE LINER ❑95. UNKNOWN <br /> -2'DOUBLE WALL ❑4. SINGLE WALL IN A VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank ❑1. BARE STEEL [13. FIBERGLASS/PLASTIC ❑5. CONCRETE ❑95.UNKNOWN 444. <br /> (Check one item only) ❑2. STAINLESS STEEL KD. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE ❑99.OTHER: <br /> REINFORCED PLASTICFRP) W/100%METHANOL <br /> TANK MATERIAL-secondary tank ❑1. BARE STEEL ❑3. FIBERGLASS/PLASTIC 8. FRP COMPTIBLE W/100%METHANOL ❑95.UNKNOWN 445. <br /> (Check one item only) ❑2. STAINLESS STEEL. STEEL CLAD W/FIBERGLASS ❑9. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑1.RUBBER LINED ❑3.EPDXY LINING ❑5.GLASS LINING ❑95.UNKNOWN 446. DATE INSTALLED 447. <br /> OR COATING ❑2.ALKYD LINING [14.PHENOLIC LINING 3-15.UNLINED ❑99.OTHER <br /> (Check one item only) <br /> OTHER CORROSION ❑1.MANUFACTURED CATHODIC 21.FIBERGLASS REINFORCED PLASTIC [195.UNKNOWN 448. DATE INSTALLED 449. <br /> PROTECTION PROTECTION [14.IMPRESSED CURRENT ❑99.OTHER <br /> (If A licable) ❑2.SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAALLED a5o. TYPE a51. O�V�FRFILL PRO,TECTIO EQUIPMENT: YEAR INSTALLED 452. <br /> (Check all that apply) [�1.SPILL CONTAINMENT Z�'ry ETI.ALARM 2i't' ❑3.FILL TUBE SHUT OFF VALVE <br /> 2'2..DROP TUBE A [BALL FLOAT c'r"'❑4.EXEMPT <br /> [ 3.STRIKER PLATE _� <br /> IV.TANK LEAK DETECTION <br /> (A description of the monitoring program shall be submitted to the local;agency.) <br /> IF SINGLE WALL TANK 453- IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br /> (Check all that apply) (Check one item only) <br /> ❑1.VISUAL(EXPOSED PORTION ONLY) ❑5.MANUAL TANK GAUGING(MTG) ❑1.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2.AUTOMATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE �2.CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3.CONTINUOUS ATG El 7.GROUNDWATER /❑3.MANUAL MONITORING <br /> ❑4.STATISTICAL INVENTORY RECONCILIATION ❑8.TANK TESTING <br /> (SIR)+BIENNIAL TANK TESTING ❑99.OTHER <br /> V.TANK CLOSURE INFORMATION/ PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455. ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456. TANK FILLED WITH INERT MATERIAL? 457. <br /> gallons ❑Yes ❑ No <br /> UPCF hwfwrc-b(1/99)-1/4 http://www.unidocs.org Rev.02/16/00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.