Laserfiche WebLink
I <br />CAL INC <br />Attn: Andrew Mittleman <br />2040 Peabody Road, Suite 400 <br />Vacaville, CA 95687 <br />Fax: (707) 446-4906 <br />Re: 7000 Michael Canlis Blvd — San Joaquin County Sheriff Motor Pool — SR0036529 <br />The permit addendum to install two Beaudraeu 404 stand-alone sensor for two under dispenser <br />containments (UDC) has been approved with the following conditions (please note that the <br />majority of the conditions were on the original permit approval, the only item added on this <br />addendum approval is (f)(iii)): <br />1. Contact local fire department, building department and San Joaquin Valley Air Pollution <br />Control District for applicable permits and requirements. <br />2. Any changes in information or scope of work must be submitted to EHD prior to <br />commencing work. <br />3. All piping and connections shall bear an UL label. <br />4. All equipment in contact with backfill must have corrosion protection. <br />5. Contact Steven C. Shih at (209) 468-9850 for the following inspections. 48-hour notice for <br />inspection appointments is required. <br />(a) If inspection reveals soil samples are required, the following information must be <br />submitted within 30 days of the sample date: <br />(i) Analytical results mailed directly from a California certified laboratory or this <br />office will not accept them. <br />(ii) See attached page 4 & 5 of the permit application for required analytical tests. <br />(iii) Hazardous Waste Manifest for piping, rinsate, or residual fuel. <br />(b) Primary piping, Secondary piping and piping slope, if piping are involved in this <br />construction. <br />(c) 24-hour lake test on UDCs. <br />(d) Spill bucket test. <br />(e) Overfill prevention must provide positive shut-off to the tank when the tank is filled to <br />no more than 95 percent of capacity as per section 2635(b)(2)(C). <br />(f) Final inspection. A final inspection must be performed prior to returning this station to <br />operation. <br />(i) A third party certified tank integrity test must be performed and results received <br />prior to scheduling the final inspection. <br />7000 Michael Canlis Blvd <br />Page 1 of 2 <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />SAN JOAQUIN COUNTY <br />c •� Donna K. Heran, R.E.H.S. <br />:< Director <br />304 East Weber Avenue, Third Floor <br />Unit Supervisors <br />Carl Borgman, R.E.H.S. <br />Al Olsen, R.E.H.S. <br />Stockton, California 95202-2708 <br />Mike Huggins, R.E.H.S., R.D.I. <br />cq�iFoaP Program Manager <br />Telephone: (209) 468-3420 <br />Douglas W. Wilson, R.E.H.S. <br />Margaret Lagorio, R.E.H.S. <br />Laurie A. Co R.E.H.S. <br />Program Manager <br />Man <br />- <br />Fax: (209) 4640138 <br />Robert McClellon, R.E.H.S. <br />Mark Barcellos, R.E.H.S. <br />April 9, 2004 <br />CAL INC <br />Attn: Andrew Mittleman <br />2040 Peabody Road, Suite 400 <br />Vacaville, CA 95687 <br />Fax: (707) 446-4906 <br />Re: 7000 Michael Canlis Blvd — San Joaquin County Sheriff Motor Pool — SR0036529 <br />The permit addendum to install two Beaudraeu 404 stand-alone sensor for two under dispenser <br />containments (UDC) has been approved with the following conditions (please note that the <br />majority of the conditions were on the original permit approval, the only item added on this <br />addendum approval is (f)(iii)): <br />1. Contact local fire department, building department and San Joaquin Valley Air Pollution <br />Control District for applicable permits and requirements. <br />2. Any changes in information or scope of work must be submitted to EHD prior to <br />commencing work. <br />3. All piping and connections shall bear an UL label. <br />4. All equipment in contact with backfill must have corrosion protection. <br />5. Contact Steven C. Shih at (209) 468-9850 for the following inspections. 48-hour notice for <br />inspection appointments is required. <br />(a) If inspection reveals soil samples are required, the following information must be <br />submitted within 30 days of the sample date: <br />(i) Analytical results mailed directly from a California certified laboratory or this <br />office will not accept them. <br />(ii) See attached page 4 & 5 of the permit application for required analytical tests. <br />(iii) Hazardous Waste Manifest for piping, rinsate, or residual fuel. <br />(b) Primary piping, Secondary piping and piping slope, if piping are involved in this <br />construction. <br />(c) 24-hour lake test on UDCs. <br />(d) Spill bucket test. <br />(e) Overfill prevention must provide positive shut-off to the tank when the tank is filled to <br />no more than 95 percent of capacity as per section 2635(b)(2)(C). <br />(f) Final inspection. A final inspection must be performed prior to returning this station to <br />operation. <br />(i) A third party certified tank integrity test must be performed and results received <br />prior to scheduling the final inspection. <br />7000 Michael Canlis Blvd <br />Page 1 of 2 <br />