M
>
MICHAEL CANLIS
>
7000
>
2300 - Underground Storage Tank Program
>
PR0232437
>
COMPLIANCE INFO_1989-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 12:52:20 AM
Creation date
6/3/2020 9:57:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1989-2008
RECORD_ID
PR0232437
PE
2361
FACILITY_ID
FA0003787
FACILITY_NAME
SHERIFFS OPERATIONS CTR #1
STREET_NUMBER
7000
Direction
N
STREET_NAME
MICHAEL CANLIS
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19305014
CURRENT_STATUS
01
SITE_LOCATION
7000 N MICHAEL CANLIS RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232437_7000 N MICHAEL CANLIS_1989-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
427
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION-FORM B ama <br /> COMPLETE A SEPARATE FORM FOR <br /> ,fAC'H TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT 3 RENEWAL PERMIT 6 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED <br /> F <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: W, <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A. OWNERS TANK 1.D.# B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MOIDAYIYEAR) D. TANK CAPACITY IN GALLONS: <br /> 11.TANK CONTENTS IF A-1 IS MARKED.COMPLETE ITEM C. <br /> A. 1 MOTOR VEHICLE FUEL 4 OIL B. C. I a REGULAR 3 DIESEL <br /> 2 PETROLEUM ❑ 80 EMPTY I PRODUCT UNLEADED H 4 GASAHOL ❑ 6 AVIATIONIGAS <br /> ❑ lb PREMIUM 7 METHANOL <br /> UNLEADED 5 JET FUEL <br /> ❑ 3 CHEMICAL PRODUCT 96 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A.1)IS NOT MARKED. ENTER NAME OF SUBSTANCE STORED C.A.S.#: <br /> Ill. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B.AND C.AND ALL THAT APPLIES IN BOX D <br /> A. TYPE OF 1 DOUBLE WALL E] 3 SINGLE WALL WITH EXTERIOR LINER E:] 96 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL E 4 SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> S. TANK ❑ 1 BARE STEEL ® 2 STAINLESS STEEL 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLEW/FRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL 95 UNKNOWN 99 OTHER <br /> C.INTERIOR <br /> F-11 RUBBER LINED ❑ 2 ALKYD LINING F-� 3 EPDXY LINING F-14 PHENOLIC LINING <br /> F-� <br /> LINING 5 GLASS LINING ❑ 6 UNLINED F--j 95 UNKNOWN 99 OTHER <br /> IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? YES— NO— <br /> D.CORROSION ❑ I POLYETHYLENE WRAP ❑ 2 COATING F--j 3 VINYL WRAP F--j 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION E:] 5 CATHODIC PROTECTION [:] 91 NONE 95 UNKNOWN J:�jk 99 OTHER <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE qRNND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U I SUCTION q L2PRESSIURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A U I SINGLE WALL A(UJ2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U I BARE STEEL A U -2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W(COATING A 100%METHANOL COMPATIBLEW/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN u OTHER <br /> D. LEAK DETECTION [:] I AUTOMATIC LINE LEAK DETECTOR 0 2 LINE TIGHTNESS TESTING E] 3 INTFA L-TORNG 0 99 OTHER <br /> MONI <br /> V.TANK LEAK DETECTION <br /> ❑ I VISUAL CHECK6 20 INVENTORY RECONCILIATION E] 3 VAPOR MONITORING❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> ❑ TANK TESTING k7 NTERSTITIAL MONITORING El 91 NONE ❑ 96 UNKNOWN ❑ <br /> 1 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAY/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH I YES SUBSTANCE REMAINING GALLONS INERT MATERIAL? NO❑ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> aPPucarlrs AE <br /> IRE) DATE <br /> I <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> STAE to COUNTY# JURISDICTION# FACILITY# <br /> TANK# <br /> Lo lo P F43T/7 <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE ERMIT EXPIRATION DATE <br /> FORM B (9-gq THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A.UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> FORoas1B•PA <br />
The URL can be used to link to this page
Your browser does not support the video tag.