My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1989-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MICHAEL CANLIS
>
7000
>
2300 - Underground Storage Tank Program
>
PR0232437
>
COMPLIANCE INFO_1989-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 12:52:20 AM
Creation date
6/3/2020 9:57:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1989-2008
RECORD_ID
PR0232437
PE
2361
FACILITY_ID
FA0003787
FACILITY_NAME
SHERIFFS OPERATIONS CTR #1
STREET_NUMBER
7000
Direction
N
STREET_NAME
MICHAEL CANLIS
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19305014
CURRENT_STATUS
01
SITE_LOCATION
7000 N MICHAEL CANLIS RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232437_7000 N MICHAEL CANLIS_1989-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
427
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM <br />TANKS <br />UNDERGROUND STORAGE TANKS -TANK PAGE 1 <br />11 (two pages per tank) <br />rage _ or _ <br />TYPE OF ACTION ❑ 1. NEW SITE PERMIT ❑ 4. AMENDED PERMIT ❑ 5. CHANGE OF INFORMATION) ❑ 6. TEMPORARY SITE CLOSURE <br />(Check one item only) ❑ 7. PERMANENTLY CLOSED ON SITE <br />V3, RENEWAL PERMIT (Soecly mason - forkrca/ use only) (Spsciy change - for local use only) ❑ S. TANK REMOVED 430 <br />BUSINESS NAME (Same as FACILITY NAME of 08A - Oorchg Business As) <br />FACIIJTY ID a <br />1 <br />%fes'® <br />LOCATION WITHIN SITE (OpticnaO 431 <br />/fs <br />® ®G EG z�w <br />L TANK DESCRIPTION <br />TANK 10 0 <br />TANK MANUFACTURER <br />COMPARTMENTALIZED TANK ❑ Yes ❑ No <br />c <br />IV N a� ®� <br />it -Yer. complete one page for each Compartment <br />DATE INSTALLED (YEARIMO) <br />TANK CAPACITY IN GALLONS <br />NUMBER OF COMPARTMENTS <br />(% <br />ADDITIONAL DESCRIPTION (Forlocal use only) <br />U. TANK CONTENTS <br />/' TANK USE 432 <br />/1. <br />PETROLEUM TYPE <br />❑ 2. LEADED <br />- <br />❑ S. JET FUEL <br />LY MOTOR VEHICLE FUEL <br />(if marked. Complete Petroleum Type) <br />ta. REGULAR UNLEADED <br />0 1C. PREMIUM UNLEADED <br />❑ 3. DIESEL <br />❑ 6. AVIATION FUEL <br />❑ 2. NON -FUEL PETROLEUM <br />❑ Ie. MiOGRAOE UNLEADED <br />❑ 4. GASOHOL <br />(:199- OTHER <br />❑ 3. CHEMICAL PRODUCT <br />COMMON NAME (from Hazardous Materials fn-ntory page) <br />CAS a (from Hazardous Materiats lmrontory page) <br />❑ 4. HAZARDOUS WASTE (Includes <br />Used 00) <br />1 (7) 9s UNKNOWN <br />111. TANK CONSTRUCTION <br />TYPE OF TANK 1 SINGLE WALL < ❑ 3.. SINGLE WALLHATH <br />C]5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM <br />,❑ <br />dem WALL EXTERIOR MEMBRANE LINER <br />C1 95. UNKNOWN " <br />(Check ono only) (y 2. DOUBLE <br />❑ 4. SINGLE WALL IN A VAULT <br />❑ 99. OTHER <br />TANK MATERIAL - primary tank C31 BARE STEEL 62"3. FIBERGLASS I PLASTIC <br />C35. CONCRETE ❑ 85. UNKNOYAV <br />(Clock one item aHyl ❑ 2. STAINLESS STEEL ❑ 4. STEEL CLAD W/FIBERGLASS <br />❑ a. FRP COMPATIBLE W/100% METHANOL ❑ 99. OTHER <br />REINFORCED PLASTIC (FRP) <br />TANK MATERIAL - secondary tank ❑ 1 BARE STEEL EX3 FIBERGLASS / PLASTIC <br />❑ 8. FRP COMPATIBLE Wf100% METHANOL ❑ 95. UNKNOWN <br />(Check one dear only) ❑ 2. STAINLESS STEEL ❑ 4. STEEL CLAD VWFIBERGLASS <br />❑ 9. FRP NON-CORROOIBLE JACKET ❑ 99. OTHER <br />REINFORCED PLASTIC (FRP) <br />® 10. COATED STEEL <br />❑ 5. CONCRETE <br />TANK INTERIOR LININGATE <br />❑ 1. RUBBERELINED ❑ 3. EPDXY LINING <br />INSTALLED <br />❑ S. GULSS LINING 95. UNKNOWN433 <br />OR COATING <br />❑ 2. ALKYD LINING ❑ 4. PHENOLIC UNING <br />❑ 6. UNLINED ❑ 99. OTHER (For local use ony) <br />(Chock one dem ) <br />DATE INSTALLEO <br />c <br />❑ 1 MANUFACTURED CATHODIC 3. FIBERGLASS REINFORCED PLASTIC 95. UNKNOWN 434 <br />OTHER CORROSION <br />PROTECTION IF APPUCAB <br />PROTECTION ❑ 4. IMPRESSED CURRENT <br />❑89. OTHER , <br />(For local use only) <br />(Check one )tem only) <br />❑ 2. SACRIFICIAL ANODE - <br />YEAR INSTALLED TYPE (1F1orlocalluse <br />OVERFILL PROTECTION EQUIPMENT. YEAR INSTALLED <br />SPILL AND OVERFILL <br />(Check aM mat apply) <br />'fonly) <br />❑ t SPILL CONTAINMENT 6 L 1114 W L -0'� ®® ❑ 1. ALARM ❑ 3. FILL TUBE SHUT OFF VALVE <br />❑ 2. DROP TUBE <br />❑ 2. BALL FLOAT ❑ 4. EXEMPT <br />- <br />❑ 3. STRIKER PLATE <br />IV. TANK LEAK DETECTION <br />IF DOUBLE WALL TANK OR TANK WITH BLADDER (Check 1040m orHy): <br />IF SINGLE WALL TANK ed Mot ap ): <br />❑ PORTION ONLY) ❑ 5. MANUAL TANK GAUGING (MTG) <br />❑ {SINGLE WALL IN VAULT ONLY) <br />1, VISUAL (EXPOSED <br />❑ VADOSE ZONE <br />,Lr4•l/2- 2 CCONTINUOUS INTERSTITIAL MONITORING <br />CONTINUOUS <br />❑ 2. AUTOMATIC TANK GAUGING (ATG) 6. <br />❑ MANUAL MONITORING <br />❑ 3. CONTINUOUS ATG ❑ 7. GROUNDWATER <br />3. <br />❑ 4. STATISTICAL INV--VTORY RECONCILIATION (SIR) ♦ ❑ 6. TANK TESTING <br />BIENNIAL TANK TESTING (199. OTHER <br />I <br />V. TANK CLOSURE INFORMATION I PERMANENT CLOSURE IN PLACE <br />ESTIMATED DATE UST USED (YR/MO/DAY) ESTIMATED OUANTITYOF SUBSTANCE REMAINING <br />43S TANK FILLED WITH INERT MATERIAL? <br />oanon$ <br />❑ Yes ❑ No <br />-,..t., CIA/GCR Form <br />
The URL can be used to link to this page
Your browser does not support the video tag.