Jan 08 1507:01a Radius Petroleum Services 20 -474-9171 p.2 <br /> D. Results of Testing/Servicing <br /> Sofhvare Version Installed: 326.01 <br /> complete the followin.4 checklist <br /> Yes _ No` Is the audible alarm operational? <br /> X Yes = No* Is the visual alar operational? <br /> a Yes ❑ No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> N Yes ❑ No' Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their <br /> proper o eration? <br /> ❑ Yes ❑ No' If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? <br /> 0 N/A <br /> ❑ Yes ❑ No' For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system <br /> rM NIA detects a leak,fails to operate,or is electrically disoonnected? If yes:which sensors initiate positive shut-down? (check ail that apply) <br /> I Sump/Trench Sensors; 2( Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks ar sensor <br /> failureldisconnection? 3 Yes; C No. <br /> Yes 7 No* For tank systems that utilize the monitaring system as the primary tank overfill warning device(i.e. no mechanical overfill prevention <br /> ❑ WA valve is installed),is the overfill waming a(atr�t visible and audible at the tank fill point(s)and operating properly? If so,at what percent <br /> of tank capacity does the alarm tri r? �U % <br /> A Yes* :iNo Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the <br /> manufacturer name and model for all replacement parts in Section E below. <br /> ❑ Yes* Z No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply)❑Product: E Water. If <br /> es,describe causes in Section E,below. <br /> ® Yes o No* Was monkoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> 0 Yes ❑ No" Is all monitoring equipment operational per manufacturer's specifications? <br /> 'In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: Regarding question six pressurized piping system and why it is marked N//A <br /> The system is a suction system not a pressurized one,but the pumping units <br /> do shut down in relation to pear UDC's and piping sumps <br /> Regarding question number seven I believe The monitoring system iS listed <br /> as the primary overfill device.The tanks also have mechanical overfill <br /> pre )ntien valves installed <br /> Monitoring System Certification Page 2 of 4 I WO? <br /> 2 2/21/07 <br />