My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MICHAEL CANLIS
>
7000
>
2300 - Underground Storage Tank Program
>
PR0232437
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2023 1:25:56 PM
Creation date
6/3/2020 9:57:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0232437
PE
2361
FACILITY_ID
FA0003787
FACILITY_NAME
SHERIFFS OPERATIONS CTR #1
STREET_NUMBER
7000
Direction
N
STREET_NAME
MICHAEL CANLIS
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19305014
CURRENT_STATUS
01
SITE_LOCATION
7000 N MICHAEL CANLIS RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232437_7000 N MICHAEL CANLIS_2009-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
470
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Secondary Containment Testing Report Form-Page 2 of 5 <br /> D. Testing of Tank Annular Spaces/Vaults ❑N/A(No tanks have secondary containment) <br /> Test Method Developed By: ❑Tank Manufacturer;❑Industry Standard;❑PE;❑Other(Spec): <br /> Test Method Used: ❑Pressure; ❑Vacuum; ❑Hydrostatic; ❑Other(Specie): <br /> Test Equipment Used: Equipment Resolution: <br /> Tank#: Tank#: Tank#: Tank#: <br /> Is Tank Exempt From Testing? ❑Yes; ❑No ❑Yes; ❑No ❑Yes; ❑No ❑Yes; ❑No <br /> Tank Capacity(gallons): <br /> Product/Grade Stored in Tank: <br /> Tank Manufacturer: <br /> Tank Model: <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> starting test(minutes): <br /> Test Start Time: <br /> Initial Reading(Rj): <br /> Test End Time: <br /> Final Reading(RF): <br /> Change in Reading(RF—Rt): <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: ❑Pass; ❑Fail ❑Pass; ❑Fail ❑Pass; ❑Fail ❑Pass; ❑Fail <br /> Was leak detection sensor <br /> properly replaced and verified ❑Yes;El No; ❑Yes;❑No; ❑Yes;❑No; ❑Yes;El No; <br /> as functional after v ❑N/A(Not Removed) El N/A(Not Removed) E]N/A(Not Removed) ED N/A(Not Removed) <br /> E. Testing of Secondary Piping or Containment Trenches ❑N/A(No piping 21 containment) <br /> Test Method Developed By: ❑Pipe/Trench Manufacturer; Industry Standard;❑PE;❑Other(Spec): <br /> Test Method Used: Pressure; ❑Vacuum; ❑Hydrostatic; ❑Other(Spec): <br /> Test Equipment Used: SSEquipment Resolution:12 <br /> 5 <br /> Pipe Run#: Pipe Run#: Pipe Run#: Pipe Run#: <br /> Pipe/Trench Manufacturer: <br /> Pipe/Trench Model: <br /> Product/Gradein Line: <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> starting test(minutes): �✓ M <br /> Test Start Date/Time: / <br /> Initial Reading(Rj): IAS I <br /> Test End Date/Time: <br /> Final Reading(RF): i <br /> Change in Reading(RF—RI): 0 <br /> Pass/Fail Threshold or Criteria: tjo, sof 5 <br /> Test Result: ❑Pass; ❑Fail ❑Pass; ❑Fait Pass; ❑Fail ❑Pass; ❑Fail <br /> UN-054-2/5 www.unidocs.org 02126/02 <br />
The URL can be used to link to this page
Your browser does not support the video tag.