My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
7373
>
2300 - Underground Storage Tank Program
>
PR0232494
>
COMPLIANCE INFO_2009-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2023 12:52:58 PM
Creation date
6/3/2020 9:57:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2013
RECORD_ID
PR0232494
PE
2361
FACILITY_ID
FA0002602
FACILITY_NAME
KAISER PERMANENTE
STREET_NUMBER
7373
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09416023
CURRENT_STATUS
01
SITE_LOCATION
7373 WEST LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232494_7373 WEST_2009-2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
429
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
File MH29667 Page Tl -2 of 2 Issued: 2005-09-08 <br />SIMULATED USE RESISTANCE TO FLUIDS TEST (FIBERGLASS REINFORCED PLASTIC SUMP <br />MATERIALS): <br />METHOD <br />One sample assembly as described in Item B was placed in a container <br />filled with each of the fluids Listed below such that the fittings inside the <br />container were completely covered with the fluids. The samples and fluids <br />were maintained at a temperature of 100°F throughout the exposure. Following <br />30 days in this condition, the containers were subjected to an internal <br />pressure of 4.5 psig (based on a maximum sump depth of 10.3 ft.) for a period <br />of at least 5 min. while the samples were examined for evidence of leakage. <br />100% Methanol <br />50% Methanol/50% ASTM Reference Fuel C <br />15% Ethanol/85% ASTM Reference Fuel C <br />10% Ethanol/90% ASTM Reference Fuel C <br />15% MTBE/85% ASTM Reference Fuel C <br />RESULTS <br />There was no evidence of leakage <br />SIMULATED USE RESISTANCE TO FLUIDS TEST (FIBERGLASS REINFORCED PLASTIC SUMP <br />MATERIALS): <br />One sample assembly as described in Item C was placed in a container <br />filled with each of the fluids Listed below such that the fittings inside the <br />container were completely covered with the fluids. The samples and fluids <br />were maintained at a temperature of 100°F throughout the exposure. Following <br />30 days in this condition, the containers were subjected to an internal <br />pressure of 4.5 psig (based on a maximum sump depth of 10.3 ft.) for a period <br />of at least 5 min. while the samples were examined for evidence of leakage. <br />100% Methanol <br />50% Methanol/50% ASTM Reference Fuel C <br />100% Ethanol <br />50% Ethanol/50% ASTM Reference Fuel C <br />15% Ethanol/85% ASTM Reference Fuel C <br />10% Ethanol/90% ASTM Reference Fuel C <br />15% MTBE/85% ASTM Reference Fuel C <br />RESULTS <br />There was no evidence of leakage <br />
The URL can be used to link to this page
Your browser does not support the video tag.