Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 -` - <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd I1 � <br /> nderrun tolra Tank ro r Inspection Repod' <br /> Facility Name: Facility Address: Date: <br /> KAISER PERMANENTE STOCKTON July 07, 2016 <br /> ti> <br /> UST System!Obselrvat'ott`s <br /> 326 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 327 HSC 25298(b) Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 328 HSC 25298(c) Failed to comply with permanent closure requirements ❑V ❑R ❑COS <br /> 329 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system ❑V ❑R ❑COS <br /> ressur�zed P"!'p-' <br /> ,!ng, <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> lfeolattons <br /> 2010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V ❑R ❑COS <br /> tf h r l SU . Y <br /> CLIS811 or MINOR ,NoticetoCortiply <br /> _ 115, <br /> a teuass I, ) <br /> Item# Remarks <br /> 105 CCR 2632 Monitoring and response plans not current or approved by the EHD. <br /> The monitoring plan is not current and/or not approved by the EHD. The monitoring plan states in the section " Pipe <br /> Monitoring is Performed Using the following Methods"the" Leak Senso Model" is listed as a 794380-205. This is <br /> incorrect. The correct model is 0794380-208. The monitoring plan must be uploaded to the California Environmental <br /> Reporting System (CERS).Immediately log into CERS, make the necessary changes, and submit for review by the <br /> EHD. <br /> This is a minor violation. <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be accessible <br /> on site at all times. Immediately locate and retain a copy on site. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator on the day of inspection. The EHD has written the <br /> complete report which replaces the initial checklist. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, within 30 days of receiving the complete inspection report. <br /> Page 3 of 4 <br />