U: <br />Ted Stephenson a -- <br />Opy <br />Belshire Environmental• <br />25971 Towne Centre Dr. <br />Foothill Ranch, CA 92610 <br />Re: Kaiser Permanente, 7373 West Lane, Stockton, CA 95210 SR0071064 <br />The San Joaquin County Environmental Health Department (EHD) has completed the review of <br />the Amended application for a permit to install new Veeder Root TLS 350 and all associated <br />sensors and probes. The Amended scope of work includes installing remote Annunciator, <br />breaking ground to fix electrical conduits and install Icon electrical penetrations on the <br />underground storage tank (UST) system at the above noted address. The permit has been <br />approved with the following conditions: <br />Contact the local fire department and the San Joaquin Valley Air Pollution Control <br />District for any applicable permits and requirements. <br />2. Any changes in information and scope of work must be submitted to EHD for approval <br />prior to commencing work. All new addenda supersede the previous ones. <br />3. Contact Fatinah Zareef at (209) 953-7311 to arrange the following inspection <br />appointments (a 48-hour notice is required for inspection appointments). Please be <br />aware that inspections for emergency work must be scheduled within five days of permit <br />approval. <br />a. Sensor functionality: Functionality of the monitoring system must be verified to <br />ensure that monitoring has been restored to meet the requirements of Title 23 <br />California Code of Regulations and the Health & Safety Code. <br />b. Overfill prevention verification: Verify that external audio and visual alarm activates <br />when tank is 90% full. <br />c. 24-hour hydrostatic test (or equivalent) on diesel piping sump after concrete is <br />poured. <br />Please be aware that the facility cannot operate the UST system or receive fuel in <br />the diesel tank prior to the EHD inspection and approval. <br />4. Since concrete will be broken near the UST and piping, a secondary containment test <br />must be performed on the UST and piping once concrete is poured in accordance with <br />the manufacturer's guidelines. <br />0 0) <br />San Joaquin County <br />Environmental Health Department <br />DIRECTOR <br />1868 East Hazelton Avenue <br />Linda Turkatte, REHS <br />Stockton, California 95205-6232 <br />PROGRobert McClAM e101 COORDINATORS <br />' <br />Jeff Carruesco, REHS, RDI <br />P <br />we www.sjgov.org/ehd <br />Kasey Foley, REHS <br />i F p'R <br />Phone: (209) 468-3420 <br />Rodney Estrada, REHS <br />Adrienne Ellsaesser, REHS <br />Fax: (209) 464-0138 <br />March 18, 2015 <br />Ted Stephenson a -- <br />Opy <br />Belshire Environmental• <br />25971 Towne Centre Dr. <br />Foothill Ranch, CA 92610 <br />Re: Kaiser Permanente, 7373 West Lane, Stockton, CA 95210 SR0071064 <br />The San Joaquin County Environmental Health Department (EHD) has completed the review of <br />the Amended application for a permit to install new Veeder Root TLS 350 and all associated <br />sensors and probes. The Amended scope of work includes installing remote Annunciator, <br />breaking ground to fix electrical conduits and install Icon electrical penetrations on the <br />underground storage tank (UST) system at the above noted address. The permit has been <br />approved with the following conditions: <br />Contact the local fire department and the San Joaquin Valley Air Pollution Control <br />District for any applicable permits and requirements. <br />2. Any changes in information and scope of work must be submitted to EHD for approval <br />prior to commencing work. All new addenda supersede the previous ones. <br />3. Contact Fatinah Zareef at (209) 953-7311 to arrange the following inspection <br />appointments (a 48-hour notice is required for inspection appointments). Please be <br />aware that inspections for emergency work must be scheduled within five days of permit <br />approval. <br />a. Sensor functionality: Functionality of the monitoring system must be verified to <br />ensure that monitoring has been restored to meet the requirements of Title 23 <br />California Code of Regulations and the Health & Safety Code. <br />b. Overfill prevention verification: Verify that external audio and visual alarm activates <br />when tank is 90% full. <br />c. 24-hour hydrostatic test (or equivalent) on diesel piping sump after concrete is <br />poured. <br />Please be aware that the facility cannot operate the UST system or receive fuel in <br />the diesel tank prior to the EHD inspection and approval. <br />4. Since concrete will be broken near the UST and piping, a secondary containment test <br />must be performed on the UST and piping once concrete is poured in accordance with <br />the manufacturer's guidelines. <br />