PE
2361
FACILITY_ID
FA0000483
FACILITY_NAME
BILLS 76
STREET_NUMBER
633
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04321055
CURRENT_STATUS
01
SITE_LOCATION
633 E VICTOR RD STE A
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232519_633 E VICTOR_1991-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
551
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
13. TANK(s) TO BE INSTALLED <br />NA A. Steel -clad with fiberglass reinforced plastic. <br />NA B. Holiday test required immediately before "setting" tank(s) (35,000 - <br />40,000 volts). [Section 2635 (b) (4)] <br />C. Fiberglass [Sections 2635 (3) and 2631 (p)] <br />A (1) Striker plate dimensions and materials. <br />A (2) Striker plate under all accessible openings. <br />A -1 (3) Installation instructions require air testing and soaping <br />prior to installation. <br />NA D. Non -clad steel tank [Section 2635 (b)] <br />N A (1) Cathodic protection provided for entire tank, piping and <br />components (nuts, bolts, washers, etc.). <br />NA (2) Approved by a corrosion engineer or N.A.C.E. <br />technician. <br />N A (3) Document stating inspection method and frequency <br />(minimum semi-annual inspection requirement). <br />N A E. Other types of tanks. <br />(1) Chemical composition of material stored is provided. <br />(2) Chemical abstract service number (CAS#) <br />14. Overflow protection systems (detail drawing of spill catchment basins)/piping <br />sump(s) required). [Section 2635 (b) (8)] <br />r - <br />G A. Spill catchment basin. <br />5 <br />Capacity <br />OK <br />Type. <br />CJ6 ®121 2 <br />5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.