COMPLIANCE INFO_1991-2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1960
>
2300 - Underground Storage Tank Program
>
PR0232534
>
COMPLIANCE INFO_1991-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
6/3/2020 9:57:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1991-2004
RECORD_ID
PR0232534
PE
2361
FACILITY_ID
FA0004547
FACILITY_NAME
CHEVRON STATION #201383
STREET_NUMBER
1960
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23402001
CURRENT_STATUS
01
SITE_LOCATION
1960 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232534_1960 W ELEVENTH_1991-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
499
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
: <br /> STATE OF CALIFORNIA4 <br /> - <br /> STATE WATER RESOURCES CONTROL BOARDDEC 2 2 iG92 <br /> UNDERGROUND STORAGE TANK PERMIT APPLICg% <br /> At., HE. <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. PER MIT15r-til <br /> MARK ONLY 211 NEW PERMIT F7 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY <br /> ONE ITEM F7 2 INTERIM PERMIT F7 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVE <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-- SPECIFY IF UNKNOWN K� <br /> A. OWNER'S TANK I.D.* VPYB. MANUFACTURED BY: 116je- <br /> ,- I A&I__ <br /> C. DATE INSTALLED(MO/DAY/YEAR) 7- <br /> EAR) 1 <br /> 1),Y D. TANK CAPACITY IN GALLONS: <br /> 11.TANK S2NTENTS IFA-1 IS MARKED,COMPLETE ITEM C. <br /> REGULAR <br /> A. [?5'1 MOTOR VEHICLE FUEL F74 OIL B. C. ❑ <br /> la UNLEADED 3 DIESEL ❑ 6 AVIATION GAS <br /> F7 2 PETROLEUM F7 80 EMPTY ❑ 1 PRODUCT ❑ 1b PREMIUM 4 GASAHOL 7 METHANOL <br /> UNLEADED El 5 JET FUEL LJ <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED [:] 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED �ID Wbe?vleo <br /> 111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.8,AND C,AND ALL_THAT APPLIES IN BOXO AND E <br /> A. TYPE OF N?11"1 DOUBLE WALL F-] 3 SINGLE WALL WITH EXTERIOR LINER E 95 UNKNOWN <br /> SYSTEM F7 2 SINGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTED TANK) F-] 99 OTHER <br /> B. TANK 7] 1 BARE STEEL ❑ 2 STAINLESS STEEL �3 FIBERGLASS E:] 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE 6 POLYVINYL CHLORIDE 7 ALUMINUM 8 1009/6 METHANOL COMPATIBLEW/FRP <br /> (Primary Tank) 9 BRONZE 10 GALVANIZED STEEL 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR 1 RUBBER LINED ❑ 2 ALKYD LINING F73 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING .5 GLASS LINING ❑ 6 UNLINED 7 95 UNKNOWN ❑ 99 OTHER <br /> IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES— NO <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP �4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE ❑ 95 UNKNOWN a 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION Ao 2 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A(T 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U I BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A Loll FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEELW/COATING A U 8 100% METHANOL COMPATIBLE WIFRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> [��J�I <br /> D. LEAK DETECTION [�l AUTOMATIC LINE LEAK DETECTOR C?2 LINE TIGHTNESS TESTING MONITORING [::] 99 OTHER <br /> V.TANK LEAK DETECTION <br /> 1 VISUAL CHECK1�i,2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING 4 AUTOMATIC TANK GAUGING [:] 5 GROUND WATER MONITORING <br /> 6 TANK TESTING Z"7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWNQ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAY/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES [:] NO <br /> SU�� GALLONS <br /> REMAINING INERT MATERIAL 7 <br /> _ <br /> THIS FORM HAS BEEN COMPLETED UNDE13,ffENA L TY OF PEqjUR_Y,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANT'S NAME DATE <br /> (PRINTED&SIGNATURE <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FpU`R NUMBERS BELOW----' <br /> COUNTY# JURISDICTION# FACILITY# TANIK <br /> I In <br /> STATE 04 F <br /> C)C/ <br /> PERMIT NUMBER PERMILU AP AT <br /> (,PROVED BY/D IT EXPIRATION DATE <br /> FORM B (7-91) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION•-reW**,-Uff1ESS A CURRENT FORM A HAS BEEN FILED. <br /> • • �j�j �3,j,L IG) W FOR00348-RS <br />