Laserfiche WebLink
06/06/2002 10:33 2093653 TANKNOLOGY • <br />monitoring System Certifica►tiOn <br />site Address: 1960W. 11TH STREET Data of Testing/Servioe. 06/04/2002 <br />Results of Testing/Servicing <br />Software Version Insta11�V.02 <br />complete the following Oback.liis- <br />PAGE 08 <br />x YO& <br />n No <br />I the audible alarm operational? <br />Q Yeti <br />Nn <br />Is the visual alarm operational? <br />S YRS <br />Were all sensors visually inspected, functionally tested, end confirmed operational? <br />El Yes <br />_LLNati <br />Nc <br />Were all sensors installed at lowest point of secondary conUnmeht and positioned so that other equipment will not <br />Interfere with their proper operation? <br />Y" <br />N:, <br />r;,,, <br />If alar ns are reloyed to a remote monitoring station, is all communications equipment (e.g. modem) operational? <br />© Yes <br />❑ No <br />© N r A <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />monttiring system detects a taak'fallsto °� rata, or is electrically disconnected? if yea: which sensors initiate positive <br />shut•clown? (check all that apply) ix Sumplfrerch Sonoma: 0 Dispenser CothtaInmhent Sensors. <br />Did you confirm positive shut -down dura to leaks and.Lensor feilure/disoonnection? El Yes _12No <br />C Yos <br />Nv <br />[JN /A <br />For lank systems that utilize the MWItbttng system as the primary tank overfill warning device (I.e.: no mechanical <br />overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill points(s) arid operating <br />property? If so, at what percent of tank capacity does the alarm trigger? s <br />Ys.* <br />©N:, <br />Was any monitoring equipment replaced? If you, idehtify specific eehsofs, probes, or othar equipment replaced and list the <br />manufacturer name and model for all rektoement parls in Section E, below, <br />yyt <br />© N, <br />Was liquid found inside any secondary containment systems designed as dry systems? (check all that apply) Product; <br />❑ Water If yes, describe causes in Section E, below. <br />© yes <br />N.. <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set-up reports, if applicable. <br />© Yet <br />Nv <br />is rill rnonitonng equipment operational per manufacturers' specifications? <br />Lon 6 below, describe hc-w ,:;:, ,.•hmi 'ht-l;e deficiences were or will be corrected. <br />S. Comments <br />page 2 of 3 <br />