My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1991-2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1960
>
2300 - Underground Storage Tank Program
>
PR0232534
>
COMPLIANCE INFO_1991-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
6/3/2020 9:57:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1991-2004
RECORD_ID
PR0232534
PE
2361
FACILITY_ID
FA0004547
FACILITY_NAME
CHEVRON STATION #201383
STREET_NUMBER
1960
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23402001
CURRENT_STATUS
01
SITE_LOCATION
1960 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232534_1960 W ELEVENTH_1991-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
499
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-.NDIVIDUAL TANKINFORMATION <br />Tanknlabgy <br />TEST DATE: 05/12/99 WORK ORDER NUMBER2208534 <br />CLIENT:CHEVRON, U. S.A. AUSTIN, TEXAS 78757 (512) 451-6334 SITE:CHEVRON STATION #201383 <br />Tank ID: 87 3 <br />Tank manifolded: No <br />Bottom to top fill in inches: <br />92.0 <br />Product: REG UNLEAD <br />Vent manifolded: No <br />Bottom to grade in inches: <br />Capacity in gallons: 11,682 <br />Vapor recovery manifolded: YES <br />Fill pipe length in inches: <br />Diameter in inches: 92.00 <br />Overfill protection: YES <br />Fill pipe diameter in inches: <br />4.0 <br />Length in inches: 411 <br />Overspill protection: YES <br />Stage I vapor recovery: <br />DUAL <br />Material: DW FIBERG <br />Installed: ATG <br />Stage 11 vapor recovery: <br />BALANCE <br />CP installed on: <br />COMMENTS <br />..Start <br />(in) <br />End (in) <br />Dipped Water Level: <br />New/passed Failed/replaced New/passed <br />Failed/replaced <br />L.D. #1 L.D. #1 L.D. #2 <br />L.D. #2 <br />Dipped Product Level: <br />Probe Water Level: <br />Make: <br />VEEDERROOT <br />Ingress Detected: Water Bubble Ullage <br />Model: <br />P.L.D. <br />S/N: <br />Test time: <br />Open time in sec: <br />Inclinometer reading: <br />: <br />Holding psi: <br />VacuTect Test Type: <br />NOT <br />Resiliency <br />NOT <br />VacuTect Probe Entry Point: TESTED <br />Test leak rate ml/m: <br />189.0 TESTED <br />Pressure Set Point: <br />Metering psi: <br />10 <br />Tank water level in inches: <br />Calib. leak in gph: <br />3.00 <br />Water table depth in inches: <br />Results: <br />PASS <br />Determined by (method): <br />Result: <br />COMMENTS <br />COMMENTS <br />DW FSBERG <br />Material: <br />Diameter (in): <br />2.0 <br />Length (ft): <br />150.0 <br />Test psi: <br />Bleedback cc: <br />Test time (min): <br />NOT NOT <br />NOT NOT <br />Start time: <br />TESTED TESTED <br />TESTED TESTED <br />End time: <br />Final gph: <br />Result: <br />Pump type: <br />PRESSURE <br />Pump make: <br />FE PETRO <br />COMMENTS <br />Impact Valves Operational: UNKNOWN <br />Printed 05/21/1999 10:28 <br />
The URL can be used to link to this page
Your browser does not support the video tag.