My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1991-2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1960
>
2300 - Underground Storage Tank Program
>
PR0232534
>
COMPLIANCE INFO_1991-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
6/3/2020 9:57:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1991-2004
RECORD_ID
PR0232534
PE
2361
FACILITY_ID
FA0004547
FACILITY_NAME
CHEVRON STATION #201383
STREET_NUMBER
1960
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23402001
CURRENT_STATUS
01
SITE_LOCATION
1960 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232534_1960 W ELEVENTH_1991-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
499
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
)RING PROCEDURES DOUBLE CONI <br />NUOUS ELECTRONIC MONITORI <br />VED PIPING <br />SUMPS <br />DOUBLE CONTAINED PIPING <br />INTERSTITIAL SPACE MONITOR: X LIQUID <br />SUMP MONITOR: X LIQUID SENSOR Veeder-Root TLS -350 Single Float Series 7943 <br />EQUIPMENT AT THIS FACILITY IS: Veeder-Root TLS -350 PLLD Series 8484 <br />All double contained piping is continuously monitored electronically by a system that can sense a <br />leak at of 3 gallons or more per hour at 10 lbs. per square inch of line pressure within 1 hour at more <br />than one location with positive shut down. The line pressure monitor is capable of sensing a <br />pressure loss in the system and disables the flow of product through the lines. All product lines are <br />sloped down towards the tank, and if the pressure sensor is activated, any liquid in the annular <br />space will flow backwards toward the sump area. There is a sensor in the sump area that detects <br />any liquid present there. The system has both visible and audible alarms that are activated when <br />there is liquid in the sump or detected in the secondary containment. At least annually, the system <br />is capable of detecting a release from the primary piping equivalent to .1 gph defined at 150% <br />operating pressure. <br />RESPONSE PLAN <br />If the system goes into the alarm mode, the Operator or his designate will check the alarm panel to <br />verify that there is a leak condition and then silence the audible alarm. The Operator or his designee <br />will immediately contact Chevron dispatch and advise them of the situation so that they can contact <br />the appropriate personnel who will follow the instructions outlined in the "Leak Response Plan", <br />which is part of your Hazardous Material Management Plan. All follow up will be completed within <br />the month the problem occurred. <br />The monitoring system will be inspected daily. The Operator or an employee appointed by the <br />Operator will follow the same procedures as outlined for monitoring the double contained product <br />tanks. <br />PREVENTATIVE MAINTENANCE <br />The monitoring equipment shall be inspected and certified annually. Maintenance will be performed <br />annually or as needed. All work performed to the monitoring system will be in accordance to the <br />manufacturers recommendations. <br />TRAINING <br />Tank operators are trained on the proper operations of the monitoring equipment per the <br />manufacturer's instructions. <br />Chevron Maintenance Dispatch (24 Hour) 1-800-423-3528 <br />
The URL can be used to link to this page
Your browser does not support the video tag.