My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1991-2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1960
>
2300 - Underground Storage Tank Program
>
PR0232534
>
COMPLIANCE INFO_1991-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
6/3/2020 9:57:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1991-2004
RECORD_ID
PR0232534
PE
2361
FACILITY_ID
FA0004547
FACILITY_NAME
CHEVRON STATION #201383
STREET_NUMBER
1960
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23402001
CURRENT_STATUS
01
SITE_LOCATION
1960 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232534_1960 W ELEVENTH_1991-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
499
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
09/28/98 MON 14:35 FAX 510 842 9591 CHEVRON N.WEST REGION <br />Caff1brinia Edftn,, Aiagust. I M <br />Veeder-Root <br />TLS Une Leak Detector, Series 8484 <br />* �, � �-' *N I <br />Certification: Leak rate of 0.10gph with Po=100.0% and-PFA=0%. <br />Leak Threshold: 0.05 gph (a leak is declared if the output of the measurement system exceeds this <br />threshold). <br />Applilcabillity: Gasoline, diesel, aviation Net, and solvent. <br />Specification: System is installed on pressurized r1berglass and steel piping. <br />The piping system volume must not exceed 89 gallons. <br />Tests are conducted at the line operating pressure. <br />The mechanical line leak detector must be removed from the pipeline system. <br />Waking Time: There is no waiting period between product delivery and testing. <br />Minimum waiting period between last dispensing and testing is 2.5 hours. <br />Test Period: The m1nimmm data collection (response time) is 0.3 hours. <br />Test data must be acquired and recorded by a microprocessor. <br />Calculatildins are automatically done by the microprocessor. <br />System Features: Tftis system Is permanently installed oh the pipeline and automatically tests the Kne. <br />Uses a preset threshold and a single test to determine Whether the pipeline is leaking. <br />If a leak Is declared, this system displays a message, triggers an -alarm. and shuts <br />down the dispensing system. <br />Calibration: Equipment must be checked annually and calibrated if necessary in accordance with <br />manufaN: urer's instructions. <br />Veeder-Root <br />125 Powder Forest Drive <br />Simsbury. CT 06070-2003 <br />Tel: (203) 651-2700 <br />0. . <br />212 <br />Appearanou on this fist is not to be construed as an endorsement by any regulatory agency w is it any guarantee of the performance of the <br />method or equipment. <br />19003 <br />a <br />
The URL can be used to link to this page