My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1960
>
2300 - Underground Storage Tank Program
>
PR0232534
>
COMPLIANCE INFO_2005-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
6/3/2020 9:57:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2010
RECORD_ID
PR0232534
PE
2361
FACILITY_ID
FA0004547
FACILITY_NAME
CHEVRON STATION #201383
STREET_NUMBER
1960
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23402001
CURRENT_STATUS
01
SITE_LOCATION
1960 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232534_1960 W ELEVENTH_2005-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
398
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_ Page 1" of <br />F- PTPTNG STTMP TFSTTNG <br />Test Method Developed By: ❑ Sump Manufacturer E Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum E Hydrostatic <br />❑ Other (Specie) <br />Test Equipment Used: Wayne Perry Inc. <br />Equipment Resolution: .0007" <br />Sump # <br />Sump # <br />Sump # <br />Sump # <br />Sump Diameter: <br />Y51" <br />Sump Depth: <br />%% <br />73 <br />" <br />_. _S.ump-Material- ---- — -- _._ <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />L" <br />r <br />f <br />„ <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />2 <br />3eD <br />Condition of sump prior to testing: <br />Ohl <br />Portion of Sump Tested' <br />ABOVE HIGHEST <br />PIPING PENETRATION <br />2" ABOVE HIGHEST <br />PIPING PENETRATION <br />2" ABOVE HIGHEST <br />PIPING PENETRATION <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?` <br />❑ Yes ❑ No E NA <br />❑ Yes ❑ No NNA <br />❑ Yes ❑ No ENA <br />❑ Yes ❑ No ❑ NA <br />Turbine shutdown response time <br />NA <br />NA <br />NA <br />Is system programmed for fail-safe <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No E NA <br />❑ Yes ❑ No ENA <br />❑ Yes ❑ No ❑ NA <br />lshutdown? <br />Was fail-safe verified to be <br />operational?* <br />❑ Yes ❑No . E NA <br />❑ Yes ❑No E NA <br />❑ Yes ❑No E NA <br />❑ Yes ❑ No ❑ NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />Test Start Time: <br />Initial Reading (Ri):�lrr <br />Test End Time: <br />Final Reading (RF): <br />z5 -VI <br />e .5'2 6 51 <br />Test Duration: <br />15 Min is Min <br />15 Min 15 Min <br />15 Min 15 Min <br />15 Min 15 Min <br />Change in Reading (RF-Ri): <br />7' <br />'Oeicid4� <br />Pass/Fail Threshold or Criteria: <br />-0.0020 -0.0020 <br />-0.0020 -0.0020 <br />-0.0020 -0.0020 <br />-0.0020 -0.0020 <br />TestResult:.: ` <br />—( Pass:; ❑ Fail, • ; <br />Pass ❑Fait ' <br />Pass ❑Fail, <br />❑Pass ❑ Faii ' . <br />Was sensor removed for testing? <br />E Yes ❑ No ❑ NA <br />E Yes ❑ No ❑ NA <br />N Yes ❑ No ❑ NA <br />E Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testin ? <br />®Yes El No El NA <br />E Yes ❑ No ❑ NA <br />E Yes ❑ No ❑ NA <br />E Yes ❑ No ❑ NA <br />
The URL can be used to link to this page
Your browser does not support the video tag.