Laserfiche WebLink
MONIRING SYSTEM CERTIF TION <br />Use By All Jurisdictions Within the State of Califo <br />Authority Cited: Chapter 6.7, alth and Safety Code; Chapter 16, Division 3 Title 23, alifornia Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility, a separate <br />certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br />system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating LIST systems within 30 days of test date. <br />A. General Information <br />Facility Name: CHEVRON #201383 (N-251 <br />Site Address: 1960W. 11TH STREET <br />Facility Contact Person: MGR - HELEN <br />Make/Model of Monitoring System:TLS350 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced <br />City: TRACY <br />Contact Phone No: 836-3181 <br />Date of Testing/Service: 04/02/2007 <br />Work Order Number: 2248337 <br />CA Zip: 95376 <br />Tank ID: 1-91 <br />Tank ID: 2-89 <br />X In -Tank Gauging Probe. <br />Model: MAG <br />0 <br />In -Tank Gauging Probe. <br />Model: MAG <br />X Annular Space or Vault Sensor. <br />Model: 208 <br />Annular Space or Vault Sensor. <br />Model: 208 <br />X Piping Sump/Trench Sensor(s). <br />Model: 208 <br />© <br />Piping Sump/Trench Sensor(s). <br />Model: 208 <br />Fill Sump Sensor(s). <br />Model: <br />Fill Sump Sensor(s). <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />X Electronic Line Leak Detector. <br />Model: PLLD <br />X <br />Electronic Line Leak Detector. <br />Model: PLLD <br />Tank Overfill/High-Level Sensor. <br />Model: <br />❑ <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Other (specify equipment type and <br />model in Section E on page 2). <br />❑ <br />Other (specify equipment type and model in Section E on page 2). <br />Tank ID: 3-61 <br />Tank ID: <br />In -Tank Gauging Probe. <br />Model: MAG <br />In -Tank Gauging Probe. <br />Model: <br />X Annular Space or Vault Sensor. <br />Model: 208 <br />Annular Space or Vault Sensor. <br />Model: <br />X Piping Sump/Trench Sensor(s). <br />Model: 208 <br />Piping Sump/Trench Sensor(s). <br />Model: <br />Fill Sump Sensor(s). <br />Model: <br />H <br />Fill Sump Sensor(s). <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />■ <br />Mechanical Line Leak Detector. <br />Model: <br />X Electronic Line Leak Detector. <br />Model: PLLD <br />❑ <br />Electronic Line Leak Detector. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Other (specify equipment type and <br />model in Section E on page 2). <br />❑ <br />Other (specify equipment type and model in Section E on page 2). <br />Dispenser : 1-2 <br />Dispenser ID: 3-4 <br />X❑ Dispenser Containment Sensor(s) <br />Model: 208 <br />0 <br />Dispenser Containment Sensor(s) <br />Model: 208 <br />X❑ Shear Valve(s). <br />X <br />Shear Valve(s) <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5-6 <br />Dispenser ID: 7-8 <br />X❑ Dispenser Containment Sensor(s) <br />Model: 208 <br />X <br />Dispenser Containment Sensor(s). <br />Model: 208 <br />X❑ Shear Valve(s). <br />FX1Shear <br />Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 9-10 <br />DispenserlD: 11-12 <br />X❑ Dispenser Containment Sensor(s) <br />Model: 208 <br />X❑ <br />Dispenser Containment Sensor(s). <br />Model: 208 <br />❑X Shear Valve(s). <br />X❑ <br />Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />❑ <br />Dispenser Containment Float(s) and Chain(s). <br />If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification <br />I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this certification is information (e.g manufacturers' checklists) necessary to verify that this information is correct. <br />and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached <br />a copy of the (Check all that apply): MX System set-upX❑ Alarm history report <br />Technician Name (print): CHRISTIAN ELIAS <br />Certification No.: B33785 <br />Signature: _ <br />License. No.: <br />Testing Company Name: Tanknology Phone No.: (800) 800-4633 <br />Site Address: 8501 N. MoPac Expressway, suite 400, Austin, TX 78759 Date of Testing/Servicing: 04/02/2007 <br />Page 1 of 3 Based on CA form dated 03/01 <br />Monitoring System Certification <br />