Page -s- of / <br />7. UNDER -DISPENSER CONTAINMENT (UDC) TESTING <br />Test Method Developed By: UDC Manufacturer ❑ Industry Standard ® Professional Engineer ❑ <br />Other (Specify) <br />Test Method Used: Pressure ❑ Vacuum ❑ Hydrostatic <br />Other (Specify) <br />Test Equipment Used: Wayne Perry Inc. See Attached Testing Results Equipment Resolution: .00007 <br />Under -Dispenser Containment Number Below <br />Z <br />UDC Manufacturer: <br />UDC Material:-•-� <br />�-4 <br />UDC Depth: �$" <br />23" <br />'z4�` <br />25" <br />-Z <br />Height from UDC Bottom to Top <br />u <br />u <br />u <br />< <br />« <br />of Highest Piping Penetration: <br />10 <br />Height from UDC Bottom to1 z „ <br />' <br />'amu <br />i� <br />17-"l.Zu <br />u <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />testing: <br />2" Above Highest <br />2" Above Highest <br />2" Above Highest <br />2" Above Highest <br />Portion of UDC Tested' <br />Penetration <br />Penetration <br />Penetration <br />Penetration <br />Does turbine shut down when ❑ Yes ❑ No NA® <br />❑ Yes ❑ No NA® <br />❑ Yes ❑ No NA® <br />❑ Yes ❑ No NA® <br />UDC sensor detects liquid. <br />Turbine shutdown response time ❑ Yes ❑ No NA® <br />❑ Yes ❑ No NAM <br />❑ Yes ❑ No NA® <br />❑ Yes ❑ No NA® <br />Is system programmed for fail- ❑ Yes ❑ No NA® <br />❑ Yes ❑ No NA® <br />❑ Yes ❑ No NA® <br />❑ Yes ❑ No NA® <br />safe shutdown?* <br />Was fail-safe verified to be ❑ Yes ❑ No NA® <br />❑ Yes ❑ No NA® <br />❑ Yes ❑ No NA® <br />❑ Yes ❑ No NA® <br />operational?* <br />Wait time between applying <br />pressure/vacuum/water and 15 Minutes <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />starting test <br />Test Start Time: ` / 7 : / V, <br />"2 f 3" <br />''= S <br />Initial Reading (R): p _7,i'"S-s- /0-04(5P,9 <br />f ?4 If,'/ 7®i 7- <br />17, % �•�� %S <br />Test End Time: JZ " 73 <br />: Y3 3111159 <br />Y.*/.Y ` i <br />Final Reading (RF): le, J7 IT 04 <br />/, 736 //-707 y <br />2, 9-aSrr> 1Z•747 <br />Test Duration: 15 Min 15 Min <br />15 Min 15 Min <br />15 Min 15 Min <br />15 Min 15 Min <br />Change in Reading (RF-Ri): , vpr ev .. ce) ®/ <br />- ecc, v ® V0.0// <br />. Cpvee � CSC/ <br />Pass/Fail Threshold or Criteria: -0.0020 -0.0020 <br />-0.0020 -0.0020 <br />-0.0020 -0.0020 <br />-0.0020 -0.0020 <br />g2i_ <br />09 <br />Was sensor removed for testing? [A Yes ❑ No NAE] <br />® Yes ❑ No NA❑ <br />® Yes ❑ No NAE] <br />❑ Yes ❑ No NAE] <br />Was sensor properly replaced and ® Yes ❑ No NAE] <br />[H Yes ❑ No NAE] <br />® Yes ❑ No NAE] <br />❑ Yes ❑ No NAD <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing and recommended follow-up for failed tests) <br />Chevron # 201383 <br />1960 W. 11 Street <br />Tracy, CA 95387 <br />N05203 -SB 989 Testing <br />