ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2015
RECORD_ID
PR0232534
PE
2361
FACILITY_ID
FA0004547
FACILITY_NAME
CHEVRON STATION #201383
STREET_NUMBER
1960
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23402001
CURRENT_STATUS
01
SITE_LOCATION
1960 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232534_1960 W ELEVENTH_2011-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
323
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M <br />2 -hour* 420 -psi <br />1 -day 650 -psi <br />28 -day 750 -psi <br />* After Final Set. <br />SURFACE PREPARATION: <br />Where bonding is important, the adjacent surfaces shall be clean, sound and free from any materials <br />that may inhibit bond such as oil, asphalt, curing compounds, acids, dirt and loose debris. Roughen <br />surfaces and remove all unsound concrete. Immediately prior to placement the repair surface shall be <br />thoroughly saturated with no standing water. <br />MIXING, <br />The use of a power driven mechanical mixer, such as a mortar mixer or a drill mounted mixer, is <br />recommended. Organize work so that all personnel and equipment are in place before mixing. Use <br />clean Potable water. Rapid Set@ CONCRETE MIX may be mixed using 3 to 5 quarts of water per 60 <br />Ib. bag. Use less water to achieve higher strengths. Do NOT exceed 5 quarts of water per bag. For <br />increased fluidity and workability use Rapid Set@ FLOW CONTROL@ plasticizing admixture from the <br />Concrete Pharmacy@. Place the desired quantity of mix water into the mixing container. While the <br />mixer is running add Rapid Set® CONCRETE MIX. Mix for the minimum amount of time required to <br />achieve a lump -free, uniform consistency (usually 1 to 3 minutes). Do NOT re -temper. <br />PLACEMENT: <br />Rapid Set@ CONCRETE MIX may be placed using traditional methods. Organize work so that all <br />personnel and equipment are ready before placement. Place, consolidate and screed quickly to allow <br />for maximum finishing time. Do NOT wait for bleed water, apply final finish as soon as possible. Rapid <br />Set@ CONCRETE MIX may be troweled, floated or broom finished. On flat work Do NOT install in <br />layers, install full depth sections and progress horizontally. Do NOT install on frozen surfaces. Use a <br />method of consolidation that eliminates air voids. To extend working time use Rapid Set@ SET <br />CONTROL@ set retarding admixture. <br />CURING: <br />Water cure all Rapid Set@ CONCRETE MIX installations. Begin curing as soon as the surface has lost <br />its moist sheen. Keep exposed surfaces wet for a minimum of 1 hour. When experiencing extended <br />setting times, due to cold temperature or the use of retarder, longer cure times may be required. The <br />objective of water curing shall be to maintain a continuously wet surface until the product has <br />achieved sufficient strength. <br />TEMPERATURE: <br />Warm environmental and materials temperatures will reduce the working time of CONCRETE MIX. To <br />compensate for warm temperatures, keep material cool and use chilled mix water. Temperatures <br />below 700F (210C) will decrease the rate of strength gain and CONCRETE MIX should not be applied if <br />surface or ambient temperature is below 450F (7.20C). <br />LIMITED WARRANTY: <br />CTS Cement Manufacturing Corporation warrants its material to be of good quality, and, at its sole <br />option, within one year from date of sale, will replace defective materials or refund the purchase price <br />thereof and such replacement or refund shall be the limit of CTS's responsibility. Except for the <br />foregoing, all warranties, express or implied including merchantability and fitness for a particular <br />purpose are excluded. CTS shall not be liable for any consequential, incidental, or special damages <br />arising directly or indirectly from the use of the material. <br />CAUTION <br />CONCRETE MIX contains cement-itious materials and may cause irritation to lungs, eyes and skin. <br />Avoid contact. Use only in adequate ventilation. Do NOT breath dust. Wet mixture may cause burns. <br />Wear suitable gloves, eye protection and protective clothing. In case of skin contact, wash thoroughly <br />with soap and water. In case of eye contact, flush immediately and repeatedly with large quantities of <br />water and get prompt medical attention. In case of difficulty breathing, remove person to fresh air. If <br />difficulty breathing persists, seek medical attention. <br />