Laserfiche WebLink
_1ONITO G SYSTEM CERTIFICA N <br /> Fo By All Jurisdictions Within the State of California <br /> Authority Cited.Chapter 6.7,Health and Safety Code;Chapter 16,Division 3 Title 23,California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: CHEVRON#201383 (N-2515) City: TRACY CA Zip:95376 <br /> Site Address: 1960 W. 11 TH STREET Contact Phone No: 836-3181 <br /> Date of Testing/Service: 02/27/2009 <br /> Facility Contact Person: MGR-HELEN <br /> Make/Model of Monitoring System:VRTLS350R Work Order Number: 2264099 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> TanklD: 87 TanklD: 89 <br /> X In-Tank Gauging Probe. Model: MAG 191 In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: 407 FXI Annular Space or Vault Sensor. Model: 407 <br /> X Piping Sump/Trench Sensor(s). Model: 208 X Piping Sump/Trench Sensor(s). Model: 208 <br /> X Fill Sump Sensor(s). Model: 208 208 <br /> Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> X Electronic Line Leak Detector. Model: PLLD X Electronic Line Leak Detector. Model: PLLD <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Tank ID: 91 Tank ID: <br /> 71 In-Tank Gauging Probe. Model: MAG In-Tank Gauging Probe. Model: <br /> X Annular Space or Vault Sensor. Model: 407 Annular Space or Vault Sensor. Model: <br /> X Piping Sump/Trench Sensor(s). Model: 208 Piping Sump/Trench Sensor(s). Model: <br /> X Fill Sump Sensor(s). Model: 208 Fill Sump Sensogs). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model <br /> X Electronic Line Leak Detector. Model: PLLD <br /> Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: <br /> Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Dispenser : 1/2 Dispenser ID: 3/4 <br /> ®Dispenser Containment Sensor(s) Model:208 X Dispenser Containment Sensor(s) Model:208 <br /> XD Shear Valve(s). FXJ Shear Valve(s) <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: 7/8 <br /> Dispenser Containment Sensor(s) Model:208 X Dispenser Containment Sensor(s). Model:208 <br /> x❑ Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9/10 Dispenser ID: 11/12 <br /> xD Dispenser Containment Sensor(s) Model:208 X Dispenser Containment Sensor(s). Model:208 <br /> 0 Shear Valve(s). X Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): XD System set-up X❑Alarm history report <br /> Technician Namerint: EDWIN BUECHLER Signature: <br /> nature:) 9 <br /> Certification No.: B36970 License.No.: 743160(Class'A'General Enginering Contractor License) <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 8501 N.MoPac Expressway,suite 400,Austin,TX 78759 Date of Testing/Servicing: 02/27/2009 <br /> Monitoring System Certification Page 1 of 3 Based on CA form dated 03/01 <br />