COMPLIANCE INFO_2011-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1960
>
2300 - Underground Storage Tank Program
>
PR0232534
>
COMPLIANCE INFO_2011-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
6/3/2020 9:57:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2015
RECORD_ID
PR0232534
PE
2361
FACILITY_ID
FA0004547
FACILITY_NAME
CHEVRON STATION #201383
STREET_NUMBER
1960
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23402001
CURRENT_STATUS
01
SITE_LOCATION
1960 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232534_1960 W ELEVENTH_2011-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
323
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
]NDIVIDUAL TANK INFORMATIONAND TEST RESULTSt . .. <br />TEST DATE:02/03/12 8501 N MO PAC EXPRESSWAY, SUITE 400 WORK ORDER NUMBER2284768 <br />CLIENT:CHEVRON PRODUCTS AUSTIN, TEXAS 78759 (512) 451-6334 SITE:CHEVRON #201383 <br />Tank ID: #1 1 <br />Product: sUPREME <br />Capacity in gallons: 11,682 <br />Diameter in inches: 92.00 <br />Length in inches: 411 <br />Material: DW FISERG <br />COMMENTS <br />Start (in) <br />Dipped Water Level: <br />Dipped Product Level: <br />Probe Water Level: <br />Ingress Detected: Water <br />Test time: <br />Inclinometer reading: <br />VacuTect Test Type: <br />VacuTect Probe Entry Point: <br />Pressure Set Point: <br />Tank water level in inches: <br />Water table depth in inches: <br />Determined by (method): <br />Result: <br />COMMENTS <br />Material: <br />Diameter (in): <br />Length (ft): <br />Test psi: <br />Bleedback cc: <br />Test time (min): <br />Start time: <br />End time: <br />Final gph: <br />Result: <br />Pump type: <br />Pump make: <br />COMMENTS <br />Tank manifolded: NO <br />Vent manifolded: YES <br />Vapor recovery manifolded: YES <br />Overfill protection: YES <br />Overspill protection: YES <br />Installed: ATG <br />CP installed on: / / <br />Bubble <br />NOT <br />TESTED <br />Bottom to top fill in inches: 92.0 <br />Bottom to grade in inches: <br />Fill pipe length in inches: <br />Fill pipe diameter in inches: 4.0 <br />Stage I vapor recovery: DUAL <br />Stage II vapor recovery: ASSIST <br />End (in) <br />New/passed Failed/replaced New/passed Failed/replaced <br />L.D. #1 L.D. #1 L.D. #2 L.D. #2 <br />Make: VEEDERROOT <br />Ullage Model: ELECTRONIC <br />S/N: 177937 <br />Open time in sec: <br />Holding psi: <br />Resiliency cc: NOT <br />Test leak rate ml/m: TESTED <br />Metering psi: <br />Calib. leak in gph: 3.00 <br />Results: Pass <br />C <br />DW FISERG <br />2.0 <br />246.0 <br />NOT NOT NOT <br />TESTED TESTED TESTED <br />PRESSURE <br />FE PETRO <br />Impact Valves Operational: YES <br />NOT <br />TESTED <br />Printed 03/01/2012 07:15 <br />