My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015-2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1960
>
2300 - Underground Storage Tank Program
>
PR0232534
>
COMPLIANCE INFO_2015-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
6/3/2020 9:57:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015-2016
RECORD_ID
PR0232534
PE
2361
FACILITY_ID
FA0004547
FACILITY_NAME
CHEVRON STATION #201383
STREET_NUMBER
1960
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23402001
CURRENT_STATUS
01
SITE_LOCATION
1960 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\1960\PR0232534\RETROFIT 2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
447
PDF
View images
View plain text
San Joaquin County JUN 2 3 2016 AMENDED <br /> Environmental Health Departmentf,,�,wpy� <br /> 1868 East Hazelton Avenue, Stockton, California 9520 ;6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd- <br /> ' ui�+� ,5� �' s'iic ,�.lr..�.�, ..s+Y:���r�_.�eut�,b'?:::r•y `.-,.E,. �.: .,!'��.;a�1t?,r�S"t'. .u�^;:'rSd.,aE'�xk'9��! * -� _•_r�' _� �" su:�_. e.=S <br /> Facility Name: Facility Phone: Date: <br /> CHEVRON STATION#1201383 209 836-3181 Janua ?5, 2016 <br /> Facility Address: CERS ID: <br /> 1960 W ELEVENTH ST TRACY CA 95376 10181657 <br /> Inspection Contact: Title: Phone: <br /> Helen McCarty Manager 209 836-3181 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION-Operating Permit 2361 -UST FACILITY <br /> Consent For: I Consent Given By: <br /> O Inspection N Photos N Samples I Helen McCarty, Mana er <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> Marcos Mercado 11/04/2017 Elijah Pender raft 12/29/2017 <br /> Service Technician Manufacturer's Training <br /> Veeder Root 12122/17•VMI 02/24/17 <br /> CCR=California Code of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> ,�"'S�,. a. -.::.�` � a� x �f��� �.a-t•a<¢. - a� s�Frty r?°x 'Cts- �,6 f a r�y Ain ,:Y _ <br /> .vs�s�*'C,}-+e :� ts,.et�i�����},..''�,'a,,..s'4.,L.��tsF�,-.r!,.., u„u✓,S.-.. _a w��Y:�.P-:. ay�^!IC�,�.v"'�.-�'f�...�+,�� �i,;,:�i. n � , � -, .. _ <br /> 101 HSC 25284 No permit to operate ❑V ❑R ❑COS <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system o V ❑R ❑COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted ❑V OR o COS <br /> 104 CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current ❑V ❑R a COS <br /> 105 HSC 25286(c) Current BOE number not submitted ❑V OR o COS <br /> 106 CCR 2632 Monitoring and response plans not current or approved by the EHD ❑V ❑R a COS <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring Is performed ❑V ❑R ❑COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing ❑V ❑R ❑COS <br /> 109 CCR 2637 Failed to test secondary containment o V ❑R ❑COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days ❑V OR o COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually ❑V ❑R ❑COS <br /> 112 HSC 25284.2 Failed to test spill containers annually ❑V ❑R ❑COS <br /> 113 CCR 2638(4) Failed to submit monitoring system certification test report within 30 days c V OR ❑COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down ❑V ❑R o COS <br /> 115 CCR 2715(a) Failed to Inform the EHD of a change of designated operator within 30 days o V QR a COS <br /> 116 CCR 2715 Designated operator,service tech or Installer did not possess current[CC certification ❑V a R ❑COS <br /> 117 HSC 25292.5 Failed to conduct ELD testing on a system located within 1 000'of a public well QV a R ❑COS <br /> 118 HSC 25292.5 Failed to repair and retest system due to failed ELD test ❑V ❑R ❑COS <br /> 119 CCR 2644.1(a)(5) Failed to submit ELD test results within 60 days ❑V ❑R ❑COS <br /> 120 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after ❑V ❑R ❑COS <br /> 121 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests ❑V ❑R ❑COS <br /> 122 HSC 25299 Documents were falsified or misrepresented ❑V OR ❑COS <br /> 123 CCR 2661 Permit to repair UST system not obtained ❑V a R ❑COS <br /> 124 CCR 2635(d) Failed to submit UST Certification of Installation/Modification ❑V OR ❑COS <br /> 125 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report ❑V ❑R ❑COS <br /> 126 HSC 25404(e)(4) Failed to report program data electronically ❑V OR n COS <br /> Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).