My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015-2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1960
>
2300 - Underground Storage Tank Program
>
PR0232534
>
COMPLIANCE INFO_2015-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
6/3/2020 9:57:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015-2016
RECORD_ID
PR0232534
PE
2361
FACILITY_ID
FA0004547
FACILITY_NAME
CHEVRON STATION #201383
STREET_NUMBER
1960
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23402001
CURRENT_STATUS
01
SITE_LOCATION
1960 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\1960\PR0232534\RETROFIT 2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
447
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FILE CO <br />San Joaquin County <br />Environmental Health Department <br />—,ate-� ••.O <br />1868 East Hazelton Avenue <br />Stockton, California 95205-6232 <br />�.•i;r Website: www.sjgov.org/ehd <br />FOR <br />Phone: (209) 468-3420 <br />Fax: (209) 464-0138 <br />November 5, 2015 <br />Liddy McKenzie <br />Gettler Ryan, Inc. <br />6805 Sierra Court, Suite G <br />Dublin, CA 94568 <br />Re: Chevron -1960 W. 11th Street, Tracy, CA 95376 <br />DIRECTOR <br />Linda Turkatte, REHS <br />PROGRAM COORDINATORS <br />Robert McClellon, REHS <br />Jeff Carruesco, RENS, RDI <br />Kasey Foley, REHS <br />Adrienne Ellsaesser, REHS <br />Rodney Estrada, REHS <br />Willy Ng, REHS <br />SR0073163 <br />The San Joaquin County Environmental Health Department (EHD) has completed the review of the <br />application for a permit at the above noted address to do the following: convert the existing 91 <br />underground storage tank (UST) to diesel, convert the 89 UST to 91, replace the dispensers, replace the <br />underground dispenser containments (UDCs), reinstall the UDC liquid sensors, install new liquid sensors <br />in the tank top sumps, cold start the monitoring panel, and install new line leak detectors on all product <br />lines. The permit has been approved with the following conditions: <br />Contact the local fire department and the San Joaquin Valley Air Pollution Control District for any <br />applicable permits and requirements. <br />2. Any changes in information and scope of work must be submitted to EHD for approval prior to <br />commencing work. All new addenda supersede the previous ones. <br />3. Contact Cindy Vo at (209) 468-8257 to arrange the following inspection appointments (a 48-hour <br />notice is required for inspection appointments). <br />a. Witness soil sampling underneath the removed UDCs. <br />b. Line test on the 87, 91 and diesel primary pipe. Have a licensed tank tester conduct a 0.1 <br />gallon per hour test witnessed by EHD or the permit holder can program the monitoring panel <br />to run a 0.1 gallon per hour test and provide the results to EHD. <br />c. Secondary containment test on the UDCs and all product pipe, after backfill. <br />d. Sensor functionality: Functionality of the monitoring system must be verified to ensure that <br />monitoring has been restored to meet the requirements of Title 23 California Code of <br />Regulations and the Health & Safety Code. If it is determined that a cold start is necessary, a <br />copy of the alarm history shall be printed prior to performing the "cold start" of the Veeder <br />Root system and made available at the time of EHD inspection. <br />e. Leak detector test: 87, 91, diesel leak detectors must be tested to confirm that the device can <br />detect a leak of 3 gallons per hour at 10 psi. <br />f. Verify product line cap at non -diesel dispensers. <br />Please be aware that the facility cannot operate the UST system prior to the EHD <br />inspection and approval. <br />4. Secondary containment testing for all product piping and UDCs are required six months after <br />installation. Provide 48 hours notification to the EHD when this test is scheduled. <br />5. Any individual performing the work of a service technician must meet the following qualifications: <br />a. Possess or be employed by a person who possesses one of several permissible valid, <br />current contractor's licenses issued by the Contractors State License Board (may be issued <br />
The URL can be used to link to this page
Your browser does not support the video tag.