Laserfiche WebLink
[131 Schedule <br />[141 EC -TYPE EXAMINATION CERTIFICATE No. <br />OEM KO 06 ATEX 0508841X Rev. 3` <br />Report: 12NK12141 <br />1151 Description of Eauioment or protective system <br />The Intrinsically safe Magnatostrdctive Pius Probes, Global Magnstostrictive Probes, Magnotostdctive Sump Sensors, and Associated <br />Accessories are designed to detect the level of liquid in petroleum storage tanks, containment sumps and dispenser pans. The devices <br />are powered by an associated apparatus with suitable entity parameters. <br />Nomenclature for type: <br />Magnetostricthre Pius Probe 84636x — yzz, 84736x - yzz and 85636x - yzz <br />Global Magnetostrlctive Pius Probe 84626x —yzz <br />Megnstostrictive Sump Sensor 85706x - yzz <br />x (Sixth Digit) Specifies OEM and material <br />y (First Suffix) EEPROM programming variables <br />zz (Second and Third Suffixes) Specifies Length <br />Tempe Wrerange: <br />The ambient temperature range is -40 °C to +60 °C. <br />Electrical data: <br />intrinsically safe specifications: <br />Ur 12.6 V <br />i. 196 mA <br />Pi 0.62 W <br />Q 1.221 uF <br />4 4.00 mH <br />glatallatlon instructions: <br />See special conditions of safe use. <br />Mguntina Instructions <br />None. <br />Routine tests: <br />None. <br />1161 Rep9d No, <br />Project Report No.: 12NK12141 (Hazardous Location Testing) <br />Documents: <br />Description: Drawing No.. Rev. Level Date: <br />Safety Certification Meg Plus Probe 331671-401 M 2012-04-26 <br />Safety Certification Meg Sump Sensor 331671-020 E 2012-06-27 <br />Safety Cartdfk:ation Mag Probe Accessories 331671.038 B 2012-10-18 <br />Meg Probe installation Manual 577014-031 B N/A <br />[171 Special conditions for safe use: <br />a The devices have been evaluated in conjunction with the intrinsic safety system defined In DEMKO 06 ATEX 137480X. The <br />descriptive system documents and manuals 577014-031 and 577013-578 Included with the aforementioned certificate must be <br />followed during instailationand the appropriate Vesder Root accessories must be used. Manual 577014-031 details <br />applicable process connections in accordance with EN 60079-26. <br />o The following condition of safe use applies to the Mag Sump Sensor. Before Installing or taking Into a hazardous area, earth <br />the unit in a Safe Area to remove any static charge. Then immediately transport the unit to the Installation site; do not rub or <br />clean the unit prior to installation. Cleaning isnot required under normal service conditions: do not rub or clean the device after <br />Installation. If the unit Is not fixed to a known earth point when installed, ensure that a separate earth connection Is made to <br />prevent the potential of static discharge. When tilling or removing the unit,' use of anti -static footwear & clothing is required. <br />a The enclosure contains aluminum. Care must be taken to avoid ignition hazards due to Impact of friction. <br />U <br />00 -IC -F4056 — issue 6.2 This certificate may only be reproduced in its entirety and without any change, schedule included. Page 2 of 3 <br />