COMPLIANCE INFO_2007-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
2224
>
2300 - Underground Storage Tank Program
>
PR0232555
>
COMPLIANCE INFO_2007-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 4:34:08 PM
Creation date
6/3/2020 9:58:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2015
RECORD_ID
PR0232555
PE
2361
FACILITY_ID
FA0003679
FACILITY_NAME
CALIFORNIA STOP*
STREET_NUMBER
2224
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16313007
CURRENT_STATUS
01
SITE_LOCATION
2224 MANTHEY RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\M\MANTHEY\2224\PR0232555\PERMANENT INJUNCTION 7-19-07.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
446
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
State Water Resources Control Board Amk Page 1 of 2 <br />Home >> Water Issues ••3> Programs >> Ust >> Leak Prevention >> Lg113 >> Vendors <br />UST Programs - LG 113 <br />....-.... ............... --- ............ ................... <br />,,.,...,......,..........,....... <br />Issue Date: August 23, 1999 <br />Revision Date: March 11, 2004 <br />Vaporless Manufacturing <br />Vaporless 98LD-2000, 99LD-2000, 99LD-2200, LD -2200 Scout <br />(for Rigid and Flexible Pipelines) <br />Certification Leak rate of 3.0 gph with PD = 100% and PFA = 0%. <br />Leak 2.5 gph. <br />Threshold A pipeline system should not be declared tight if the test result indicates a loss that equals or exceeds this <br />threshold. <br />Applicability Gasoline, diesel, aviation fuel. <br />Calibration Equipment must be checked annually for capability of detecting a line leak of 3.0 gph and, if <br />necessary, calibrated in accordance with manufacturer's instructions. <br />Comments Functionality and operability of the 99 LD -2000 and 99 LD -2200 are unchanged by installation of the Leak <br />Detection Sensor (piston switch) that supports the VMI ISM -4080 and ISM -4081 Integrated Shutdown <br />Module. <br />Vaporless Manufacturing Evaluator: Ken Wilcox Associates <br />8700 East Long Mesa Drive Tel: (816) 443-2494 <br />Prescott Valley, AZ 86314 Dates of Evaluation: 05/20/98, 11/10/98 <br />Tel: (928) 775-5191 <br />http://www.waterboards.ca.gov/water issues/programs/ust/leak_prevention/lgl13/vendors/vaporless_manu... 4/1/2010 <br />Other liquids may be tested after consultation with the manufacturer. <br />Specification <br />System tests pressurized flexible, fiberglass, and steel pipelines. <br />Tests are conducted at operating pressure. <br />Pipeline <br />Maximum of 172 gallons for rigid pipelines. <br />Capacity <br />Maximum of 39.5 gallons for flexible pipelines. <br />Waiting Time <br />None between dispensing and testing. <br />None between delivery and testing. <br />Test Period <br />Response time is less than 1 minute without a leak and 1 to 8 minutes with a leak. <br />System <br />Permanent installation on pipeline. <br />Features <br />Automatic testing of pipeline. <br />Preset threshold. <br />Single test to determine if pipeline is leaking. <br />Restricted flow to dispenser if leak is declared. <br />Calibration Equipment must be checked annually for capability of detecting a line leak of 3.0 gph and, if <br />necessary, calibrated in accordance with manufacturer's instructions. <br />Comments Functionality and operability of the 99 LD -2000 and 99 LD -2200 are unchanged by installation of the Leak <br />Detection Sensor (piston switch) that supports the VMI ISM -4080 and ISM -4081 Integrated Shutdown <br />Module. <br />Vaporless Manufacturing Evaluator: Ken Wilcox Associates <br />8700 East Long Mesa Drive Tel: (816) 443-2494 <br />Prescott Valley, AZ 86314 Dates of Evaluation: 05/20/98, 11/10/98 <br />Tel: (928) 775-5191 <br />http://www.waterboards.ca.gov/water issues/programs/ust/leak_prevention/lgl13/vendors/vaporless_manu... 4/1/2010 <br />
The URL can be used to link to this page
Your browser does not support the video tag.