My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
2224
>
2300 - Underground Storage Tank Program
>
PR0232555
>
COMPLIANCE INFO_2007-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 4:34:08 PM
Creation date
6/3/2020 9:58:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2015
RECORD_ID
PR0232555
PE
2361
FACILITY_ID
FA0003679
FACILITY_NAME
CALIFORNIA STOP*
STREET_NUMBER
2224
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16313007
CURRENT_STATUS
01
SITE_LOCATION
2224 MANTHEY RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\M\MANTHEY\2224\PR0232555\PERMANENT INJUNCTION 7-19-07.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
446
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br /> prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to <br /> the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems <br /> within 30 days of test date. <br /> A. General Information <br /> Facility Name: California Stop Bldg.No. — <br /> Site Address: 2224 Manthey Road City: Stockton, CA Zip: 95206 <br /> Facility Contact Person: Timmy Le Contact Phone No: 209-406-1484 <br /> Make/Model of Monitoring System: V/R TLS 350 Date of Testing/Servicing: 3/11/2014 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific a ui ment inspected/serviced: <br /> Tank ID: 1 - 87 Tank ID: 3 - Diesel <br /> 0 In-Tank Gauging Probe. Model: MAG-1 0 In-Tank Gauging Probe. Model: MAG-1 <br /> 0 Annular Space or Vault Sensor. Model: 407 0 Annular Space or Vault Sensor. Model: 407 <br /> 0 Piping Sump/Trench Sensor(s). Model: 208 0 Piping Sump/Trench Sensor(s). Model: 208 <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> 0 Mechanical Line Leak Detector. Model: 99LD2000 0 Mechanical Line Leak Detector. Model: 99LD2000 <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment a and model in Section E on Page 2). ❑ Other(specify equipment and model in Section E on Pa e 2). <br /> Tank ID: 2 - 91 Tank ID: <br /> 0 In-Tank Gauging Probe. Model: MAG-1 ❑ In-Tank Gauging Probe. Model: <br /> 0 Annular Space or Vault Sensor. Model: 407 ❑ Annular Space or Vault Sensor. Model: <br /> 0 Piping Sump/Trench Sensor(s). Model: 208 ❑ Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> 0 Mechanical Line Leak Detector. Model: 99LD2000 ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment t and model in Section E on Pa e 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1 / 2 Dispenser ID: 7/ 8 <br /> 0 Dispenser Containment Sensor(s). Model: 208 0 Dispenser Containment Sensor(s). Model: 208 <br /> 0 Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dis nser Containment Floats and Chain(s). I ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 3 / 4 FUDispenser <br /> nser ID: <br /> 0 Dispenser Containment Sensor(s). Model: 208 Containment Sensor(s). Model: <br /> 0 Shear Valve(s). ear Valve(s). <br /> ❑ Dis enser Containment Float(s)and Chain(s). spenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5/ 6 Dispenser ID: <br /> 0 Dispenser Containment Sensor(s). Model: 208 ❑ Dispenser Containment Sensor(s). Model: <br /> 0 Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dis nser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br /> reports,I have also attached a copy of the report;(check all that apply): O System set-up O Alarm history report <br /> Technician Name(print): Al Milburn Signature: Lz_ <br /> Certification No: A27843 License No. 956593 <br /> Testing Company Name: EPIC Environmental Compliance Systems Inc. Phone No. 888-700-EPIC <br /> Testing Company Address: 1435 Huntington Ave, Suite 230 <br /> South San Francisco, CA 94080 Date of Testing/Servicing: 3/11/2014 <br /> UN-036-1/4 Page 1 of 4 Rev.06/04/01 <br /> www.unidocs.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.