My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
2224
>
2300 - Underground Storage Tank Program
>
PR0232555
>
COMPLIANCE INFO_2007-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 4:34:08 PM
Creation date
6/3/2020 9:58:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2015
RECORD_ID
PR0232555
PE
2361
FACILITY_ID
FA0003679
FACILITY_NAME
CALIFORNIA STOP*
STREET_NUMBER
2224
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16313007
CURRENT_STATUS
01
SITE_LOCATION
2224 MANTHEY RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\M\MANTHEY\2224\PR0232555\PERMANENT INJUNCTION 7-19-07.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
446
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sogov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility California Stop Address: 2224 S Manthe Road, Stockton Inspection Mar 11, 2014 <br /> Name: p y Date: <br /> Facility Title: e' <br /> Contact: Nancy Le/Thien Phan owner/ manager -7621 <br /> Inspection XRoutine XMonitoring System Certification ❑Installation ❑Complaint-ID#: I I Other: <br /> Type: <br /> (Authority HSC 25289) p, <br /> Consentfor: $Inspection ❑Sampling $Photos Granted by: N Title: <br /> Monitoring Veeder-Root TLS-350 Piping Overfill <br /> Panel: System: $Pressurized ❑Suction C Gravity prevention: (Mechanical ❑Audible/visual <br /> LIST1 2 3 <br /> - Product - - - - - - - - -------------- -87 octane ------------------------------octane DSL <br /> - - - - - - - - - - - - - - - - - - - - - - - - <br /> Designated AlJbbi ICC Exp. 100614 Violations: 11M1-Release Detection 11M2-Release Prevention ❑M3-Both <br /> Alex ar <br /> Operator: Date: <br /> On Site Service. ICC Exp. Manufacturer's <br /> Technician: Date: Training: <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=California Health and Safe Code;CCR=Califomia Code of Requations <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> 1017R25643824(d2) <br /> 4 No permit to operate <br /> 1024.5 Annual operating fees not paid <br /> 1034(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br /> monitor the tanks stem <br /> 1042.2 Current financial responsibility documents not on file with the Environmental Health Department(EHD) 11f <br /> 105Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 106 (b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 (d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br /> 108 CCR 2637 Secondary containment:(a)test not performed;(e)test report not submit ed within 30 days;(f)test notification <br /> not provided to the EHD at least 48 hours prior to conducting the test <br /> Monitoring equipment certification:(a)not performed annually;(d)test rebort"nof submitted within 30 days; <br /> 109 CCR 2638 (e)test notification not provided to the EHD at Ilyp�t 48 o s prior to conducting an installation,repair, <br /> replacement,calibration,or certification <br /> 110 HSC 25291(f) Annual line leak detector test not performed (M1) <br /> 111 HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (M7) <br /> 113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br /> permit conditions <br /> 116 HSC 25292.5 Enhanced leak detection(ELD)testing not performed on a system located within 1000'of public well,or <br /> failures not repaired and retested <br /> 117 CCR 2661 Permit to repair UST system not obtained <br /> 118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 119 HSC 25298(b) Permit to temporarily close UST system not obtained <br /> 120 HSC 25298(c) Permit to close UST system not obtained <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6%years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201 CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> equipment, round water elevations,or other test results; 6 results of inventory readings and reconciliations <br /> 202 CCR 2712(i) Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight hours (M7) <br /> 203 CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a sudden loss of <br /> product was not reported to the HD within 24 hours <br /> Inspector: Received By: Title: <br /> Thuy Tran 209 468-8257 - C <br /> EHD 23-02 Rev 04/19/12 Page 1 UST INSPECTION REPORT <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.