Laserfiche WebLink
Specifications <br />r-1 <br />Operating Temp.: <br />-250 to +13 . <br />Compatible fuels: <br />Unleaded gasoline <br />848480-002 <br />Leaded gasoline <br />F.E. Petro: <br />5% methanol/95% unleaded <br />10% ethanl/90% unleaded <br />848480-003 <br />15% MTBE/85% unleaded <br />Tokheim and Bennett: <br />Diesel <br />Red Jacket Big Flo: <br />Kerosene <br />FE Petro High Capacity: <br />Jet Fuel <br />Aviation gasoline <br />Line flow rate: <br />120 gpm. max. <br />Design: <br />Intrinsically safe <br />Operating Range: <br />0-50 psi. <br />Proof Pressure: <br />200 psi <br />Red Jacket: <br />P33R1 (1/3 HP) <br />848480-001 <br />P75S1 (3/4 HP) <br />848480-002 <br />P150Si (1-1/2 HP) <br />F.E. Petro: <br />STPR 33 (1/3 HP)* <br />STPR 75 (3/4 HP)* <br />848480-003 <br />STPR 150 (1-1/2 HP)* <br />Tokheim and Bennett: <br />23 psi ouput minimum <br />Red Jacket Big Flo: <br />P300H3-2HB (3 HP) Only <br />FE Petro High Capacity: <br />STP3 (3 HP) Only <br />*"R" designates precision check valve <br />Contact Veeder-Root for approved piping systems <br />Standard Mode(& <br />Form No. <br />Description <br />848480-001 <br />Pressurized Line Leak Detector for F.E. Petro Pumps* <br />848480-002 <br />Pressurized Line Leak Detector with in-line check valve <br />for Red Jacket and Tokheim Pumps (includes line leak <br />sensor, in-line check valve, and pump port strainer) <br />848480-003 <br />Pressurized Line Leak Detector with SwiftCheckTM for <br />Red Jacket and Tokheim Pumps (includes line leak <br />sensor and SwiftCheckTM check valve) <br />*Requires an F.E. Petro Precision Check Valve, F.E. Petro Part Number <br />400153925. Veeder-Root check valve not required. <br />TLS-35OR Consoles** Series 8482 <br />TLS -350 Consoles Series 8470 <br />"Pressurized Line Leak Interface Module, Form No. 330373-001, and Pressurized <br />Line Leak Controller Module, Form No. 330374-00 1, required for use of PLLD with <br />TLS-35OR or TLS -350 consoles. A software enhancement module is also available <br />to enable 0.1 gph leak detection for PLLD. <br />Supported Piping: 2" Fiberglass — 350' <br />3" Fiberglass —150' <br />2" Steel — 440' <br />1-1/2 Envirof►ex-400' <br />Supported Applications: . Siphon/Manifolded Tanks (Two Tanks— <br />One Pump) <br />Manifolded Lines (Two Tanks — Two <br />Pumps Into Common Line) <br />Electronic Blenders <br />No Mechanical Blenders <br />SwiftCheckTM Typical Installations <br />The SwiftCheckTM valve installs into the 2" leak detector port on the Red <br />Jacket or Tokheim submersible pump. The Veeder-Root line leak sensor <br />is then screwed into the SwiftCheckTM valve. <br />Disable the pump's functional element by removing its spring and piston. <br />In -Line Check Valve <br />The in-line check valve is threaded at both ends for a 2" NPT fitting and <br />should be installed into the submersible pump discharge. Downstream <br />from the check valve, install a 2" tee, and mount the Veeder-Root line <br />leak probe into the tee. <br />Disable the pump's functional element by removing its spring and piston. <br />Pressurized Line Leak Detector Installation Cable <br />Veeder-Root offers direct burial cable (Form No. 838100-xxx) for <br />locations where conduit does not exist. See price list for ordering <br />information. <br />SwiftCheckTM Installation Diagram In -Line Check Valve Installation diagram <br />° LINE LEAK LINE LEAK SENSOR <br />SENSOR <br />VENT SCREW <br />e - <br />00 _0I <br />i <br />SWIFfCHECK <br />® VALVE <br />7 PIPE TEE <br />IN-LINE CHECK VALVE <br />VEEDERSAWIDOT <br />Environmental Products <br />The Leader in Tank Monitoring Technology <br />125 Powder Forest Drive, Post Office Box 2003, Simsbury, CT 06070-2003 TEL: (860) 651-2700, FAX: (860) 651-2719 TECH SUPPORT: (860) 651-2753 <br />BRAZIL: Sao Paulo , CANADA: Mississauga, Ontario • ENGLAND: Richmond Surrey • FRANCE: Rungis Cedex • GERMANY: Neuhausen/Filder • SINGAPORE: Singapore <br />printery <br />AR9 in 95 <br />13292 Replaces 13180 P/N 577013-071 us A <br />C� <br />