My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1992-2000
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1103
>
2300 - Underground Storage Tank Program
>
PR0232587
>
COMPLIANCE INFO_1992-2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 10:20:59 AM
Creation date
6/3/2020 9:58:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1992-2000
RECORD_ID
PR0232587
PE
2361
FACILITY_ID
FA0004521
FACILITY_NAME
CHEVRON USA #201761*
STREET_NUMBER
1103
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
21935038
CURRENT_STATUS
01
SITE_LOCATION
1103 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232587_1103 S MAIN_1992-2000.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
323
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Vor Gar May 11:Gr raa adu o4z baba ZINYLKOINMENTAL SAFETY 19001 <br />AITORING PROCEDURES FOR DOUBLEIRLL TANKS <br />EQUIPMENT AT THIS FACILITY: Ve r+Root_TLS•350 Series 8470 <br />The Underground storage tanks are monitored using an approved continuous electronic monitoring <br />system (sea below), This system iu gable Lu duLo :t the presence of a leak in the primary as well as <br />secondary containment through the use of an annular space and submerged sensor, If an alarm or <br />failure conditions occurs, the Operator will call Chevron Maintenance Dispatch at 800.423-3528 <br />(24 hour) immediately, The Operator Will than record the alarm condition on a log along with the <br />investigative/corrective action steps followed to resolve the situation. Response to the alarm <br />condition will occur within 24 hours. <br />If the alarm condition is NOT the result of an equipment failure, then Chevron will repair the tank <br />system in accordance with all local and state requirements. If the alarm condition is the result of an <br />equipment failure, Chevron will repair the equipment as required and ensure that it is functioning <br />properly, <br />MONITORING SYSTEM <br />INTERSTITIAL MONITOR: X LIQUID FLOAT SWITCH SENSOR <br />EQUIPMENT AT THIS FACILITY: V TLS -360 Annular Space Monitor Series 784380 <br />MAINTENANCE CONTRACTOR: Chevron Maintenance Dispatch <br />The Operator or a designated employee performs visual monitoring of the tank monitor alarm box <br />daily. Please see the attached site map for the location of all equipment and forms for keeping <br />monitoring records at the site. The Operator will also perform inventory reconciliation according to <br />the procedure outlined in the Inventory reconciliation section of this plan. <br />The electronic monitoring devices are maintained according to manufacturer's recommendations. <br />Training will be given which includes Information regarding: how to self test the electronic <br />monitoring equipment, what the equipment monitors, how to tell when the alarm goes off, how to <br />perform inventory reconciliation, record keeping requirements and procedures to follow In the event <br />of alarm activation, leak, suspected leak, or other emergency. All training Is in accordance with the <br />equipment manufacturer recommendations. <br />See also "Chevron Leak Response Pian" <br />Chevron Maintenance Dispatch (24 Hour) 1400.423-3528 <br />
The URL can be used to link to this page
Your browser does not support the video tag.