My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1992-2000
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1103
>
2300 - Underground Storage Tank Program
>
PR0232587
>
COMPLIANCE INFO_1992-2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 10:20:59 AM
Creation date
6/3/2020 9:58:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1992-2000
RECORD_ID
PR0232587
PE
2361
FACILITY_ID
FA0004521
FACILITY_NAME
CHEVRON USA #201761*
STREET_NUMBER
1103
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
21935038
CURRENT_STATUS
01
SITE_LOCATION
1103 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232587_1103 S MAIN_1992-2000.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
323
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Specifications <br />System, Model X76S <br />Power: 115 Vac, 60 Hz <br />Power Consumption: 100 VA <br />Operating Temperature: 32 ° to 165°F (0 ° to 75°C) <br />Dimensions: 9x9.5x4.2 in. (22.86x24.13x10.67 cm) <br />Mounting: General purpose area; wall mount <br />fM Approved, (D Listed 48RO <br />Alarm Module <br />Field Sensor: Dry contact <br />Field Sensor Voltage: 115 Vac (supplied by X76S) <br />Number of Inputs: One per module <br />FM Approved, (D Listed 48RO <br />Intrinsically Safe Barrier Module X53 <br />Number of Inputs: Two per module <br />Sensors Voltage: 24 Vdc, current limited <br />Sensors: Dry contact <br />Output Interface to Alarm Module: Relay contact; <br />normally open/normally closed; selectable <br />Power Consumption: 750 mW per input <br />Supply Voltage: 24 Vdc from I. S. power supply <br />fM Approved, UE Listed 48RO <br />Power Supply I. S. (Intrinsically Safe) <br />Power Input: 115 Vac <br />Output Voltage: 24 Vdc <br />FM Approved, (UD Listed 48RO <br />Tank Leak Sensor, Model LS -3 N.C. <br />Housing: 304 stainless steel <br />Switch: <br />Type: SPST N.C. <br />Rating: 10 VA <br />Float material.. Buna-N <br />Pressure: 50 PSIG maximum <br />Leads: 20 AWG <br />U@ Listed 48RO <br />Tarek Leak Sensor, Model LS -7 <br />For steel and fiberglass double-wall tanks. <br />Housing Material: PVC (Geon 87241) <br />Liquid SpG:.70 minimum <br />Switch: <br />Type.. SPST N.C. <br />Rating: 10 VA <br />Leads: 20 AWG <br />�D Listed 48RO <br />Hydrostatic Tank Leak Detectors, <br />Models LS -10 or LS -20 <br />Reservoir: <br />Volume. <br />LS -10, two gallons (7.47 liters) <br />LS -20, four gallons (15.14 liters) <br />Material. Polyethylene plastic <br />Switches: Model LS -3 N.O. and LS -30 <br />Type: LS -3 N.O., SPST; LS -30, DPDT <br />Rating 10 VA <br />Float material • Buna-N <br />�I ROPJAIVRONAN <br />COMPANY ENGINEERING <br />P.O. Box 1275 <br />21200 Oxnard Street <br />Woodland Hills, <br />California 91367 U.S.A. <br />(818) 883-5211 9 Telex 698-490 <br />FAX (818) 992-6435 <br />Pressure. 50 PSIG maxim <br />Leads: 20 AWG <br />UL Listed 48RO <br />HVA Mird Liquid Vertical Riser Sensor <br />Housing: Stainless steel <br />Contacts: Gold plated <br />Float: Gold plated aluminum <br />Type: Single pole, normally open <br />Leads: 20 AWG <br />UD Listed 48RO <br />Tank Leak Sensor, Model JT -2 <br />Housing: Stainless steel, explosion proof, hermetically <br />sealed, NEMA Types 7 and 9 <br />Classification: <br />Class 1: Groups A, B, C and D <br />Class 2: Groups E, F and G <br />Switch: <br />Type: SPDT N.O. (shelf condition) <br />Rating: 10 VA <br />Electrical Connection: '/2 in. -14 NPT with PVC -insulated <br />18 AWG leads <br />Pressure: <br />Setpoints JT -2 Positive Pressure Leak Sensor, .5 PSIG, <br />JT -2V Vacuum Leak Sensor, .5 inches of mercury <br />Connection: '/ in. -18 NPT <br />Adjustment: � in. Allen wrench through port <br />Temperature Range: —400 to 180-F (-40 ° to 82-C) <br />UD Listed 48RO; CSA Approved 34146 <br />The Ronan Model X76S Leak Detector Monitor System <br />can be configured to meet the different local and state <br />codes for underground storage by proper selection of <br />sensors and monitor modules. For example, a particular <br />local code and/or type of facility may require leak detection <br />of a tank annulus. The monitor system would consist of the <br />following items: <br />Model X76S-( <br />Sensor Type <br />LS -3(°) Vertical Liquid Level <br />LS -7 Horizontal Liquid Level <br />LS -10 Hydrostatic Reservoir with LS -3 <br />LS -20 Hydrostatic Reservoir with LS -3 <br />LS -30 Dual Liquid Level <br />HVA Mw Liquid for vertical Riser <br />JT -2P Positive Pressure Leak <br />JT -2V Vacuum Leak <br />N.O.-Normally Open, <br />N.C.—Normally Closed <br />Note: Use additional lisiting if more than <br />one type of sensor is used. e.g.: <br />(2LS-3) - (1 LS -10) <br />Sensor Quantity <br />No. of Alarm inputs <br />(1 thru 4) max 4 <br />Warranty: Ronan warrants equipment of its own manufacture to be <br />free from defects in material and workmanship under normal conditions <br />of use and service, and will repair or replace any component found to be <br />defective, on its return, transportation charges prepaid, within one year <br />of its original purchase. This warranty carries no liability, either <br />expressed or implied, beyond our obligation to replace the unit which <br />carries the warranty. <br />RONAN ENGINEERING <br />LTD. U.K. <br />1 Tilley Road <br />Crowther District 3 <br />Washington. Tyne and Wear <br />United Kingdom. NE38-OEA <br />(091) 416-1689 • Telex 537.746 <br />FAX (091) 416-5856 <br />RONAN ENGINEERING <br />RONAN ENGINEERING <br />LIMITED <br />(AUST.) PTY. LTD. <br />32 Bermondsey Road <br />Unit ]0, 8 Leighton Place <br />Toronto, Ontario <br />Hornsby, N.S.W. 2077 <br />Canada M4B1Z5 <br />Australia <br />(416) 752.0310 • Telex 63662 <br />(02) 477-7344 0 Telex 73467 <br />FAX (416) 752-8072 <br />FAX (02) 477-6151 <br />X76S / 190 Printed in the U.S.A. <br />1-1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.