Laserfiche WebLink
' P,7J3nidwWcW ONITORING SYSTEM CERTIFICATION <br /> s` <br /> e By All Jurisdictions Within the State of Califomi <br /> Authority Cited:Chapter 6.7, and Safety Code,Chapter 16,Division 3 Title 23,Oomia Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: CHEVRON 201761 City: MANTECA CA Zip:95337 <br /> Site Address: 1103 S.MAIN ST. Contact Phone No:825-0174 <br /> Facility Contact Person: MANAGER <br /> Date of Testing/Service: 06/03/2002 <br /> Make/Model of Monitoring System: VEEDER ROOT TLS Work Order Number: 2222210 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: SUPER Tank ID: PLUS <br /> X In-Tank Gauging Probe. Model: 847390 X In-Tank Gauging Probe. Model: 847390 <br /> X Annular Space or Vault Sensor. Model: 794390-407 Annular Space or Vault Sensor. Model: 794390-407 <br /> 71 Piping Sump/Trench Sensor(s). Model: 794380-208794380-208 <br /> Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: PLLD :X:1 Electronic Line Leak Detector. Model: PLLD <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Tank ID: KEQUEAR Tank ID: <br /> X In-Tank Gauging Probe. Model: 847390 In-Tank Gauging Probe. Model: <br /> )( Annular Space or Vault Sensor. Model: 794390-407 Annular Space or Vault Sensor. Model: <br /> X Piping Sump/Trench Sensor(s). Model: 794380-208 Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> X Electronic Line Leak Detector. Model: PLLD Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Otheri equipment(specify eq p ment <br /> type and model in Section E on page 2). <br /> Dispenser : 1-2 Dispenser ID: 3-4 <br /> 5q Dispenser Containment Sensor(s) Model:794380-208 X Dispenser Containment Sensor(s) Model: 794380-208 <br /> ®Shear Valve(s). Shear Valves) <br /> Ej Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5-6 Dispenser ID: 7-8 <br /> ® Dispenser Containment Sensor(s) Model:794380-208 Dispenser Containment Sensor(s). Model:794380-208 <br /> Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9-10 Dispenser ID: 11-12 <br /> ® Dispenser Containment Sensor(s) Model:794380-208 X Dispenser Containment Sensor(s). Model:794380-208 <br /> ® Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): System set-up report; Alarm history report <br /> PRINTED NAME:ANEIL CHAND SIGNATURE: 4� <br /> COMPANY: Tanknology PHONE NO: (800)800-4633 <br /> page 1 of 3 Based on CA form dated 03/01 <br />