Laserfiche WebLink
AUTO DIAL TIME SETUP: <br />D 6:SOLVONE MONTHLY TEST <br />DIAL ON DATE <br />OCT 30. 2008 <br />DIAL TIME : DISABLED <br />RECEIVER REPORTS: <br />D 7:Solvone ISD Warn <br />DIAL ON DATE <br />OCT 30, 2008 <br />DIAL TIME : DISABLED <br />RECEIVER REPORTS: <br />D 8:Solvone <br />DIAL ON DATE <br />OCT 30, 2008 <br />DIAL TIME : DISABLED <br />RECEIVER REPORTS: <br />D 7:Solvone ISD Warn <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT WARN <br />ALL:DEGRD COLLECT WARN <br />D 8:Solvone <br />IN -TANK ALARMS <br />ALL:LEAK ALARM <br />ALL:HIGH WATER ALARM <br />ALL:OVERFILL ALARM <br />ALL:LOW PRODUCT ALARM <br />ALL:MAX PRODUCT ALARM <br />ALL:GROSS TEST FAIL <br />ALL:PERIODIC TEST FAIL <br />ALL:ANNUAL TEST FAIL <br />ALL:N0 CSLD IDLE TIME <br />ALL:GROSS FAIL LINE TNK <br />LIQUID SENSOR ALMS <br />ALL:FUEL ALARM <br />ALL:SENSOR OUT ALARM <br />ALL:SHORT ALARM <br />ALL:WATER ALARM <br />ALL:WATER OUT ALARM <br />LEAK MIN PERIODIC: 0% <br />0 <br />LEAK MIN ANNUAL 0% <br />0 <br />PERIODIC TEST TYPE <br />STANDARD <br />ANNUAL TEST FAIL <br />ALARM DISABLED <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />GROSS TEST FAIL <br />ALARM DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF <br />TNK TST SIPHON BREAK :OFF <br />DELIVERY DELAY 5 MIN <br />PUMP THRESHOLD lo.00% <br />IN -TANK SETUP <br />- - - - - --- - - <br />- - - - <br />T I :SUPREME <br />PRODUCT CODE <br />I <br />THERMAL COEFF <br />:.000700 <br />TANK DIAMETER <br />92.00 <br />RECEIVER SETUP: <br />TANK PROFILE <br />4 PTS <br />FULL VOL <br />11682 <br />69.0 INCH VOL <br />9577 <br />D 6:SOLVONE MONTHLY TEST <br />46.0 INCH VOL <br />23.0 <br />5940 <br />18002640422 <br />INCH VOL <br />2272 <br />RCVR TYPE: FACSIMILE <br />PORT NO: 3 <br />RETRY NO: 3 <br />FLOAT SIZE: <br />4.0 IN. <br />RETRY DELAY: 3 <br />CONFIRMATION REPORT: OFF <br />WATER WARNING <br />1.0 <br />HIGH WATER LIMIT: <br />2.0 <br />D 7:Solvone ISD Warn <br />18004615512 <br />MAX OR LABEL VOL: <br />11682 <br />RCVR TYPE: FACSIMILE <br />OVERFILL LIMIT <br />90% <br />PORT NO: 3 <br />HIGH PRODUCT <br />10513 <br />RETRY NO: 20,,, <br />95% <br />RETRY DELAY: 3 <br />DELIVERY LIMIT <br />11098 <br />CONFIRMATION REPORT: OFF <br />0/o <br />700 <br />D 8:Solvcne <br />LOW PRODUCT <br />18002626485 <br />RCVR TYPE: FACSIMILE <br />LEAK ALARM LIMIT: <br />500 <br />99 <br />PORT NO: 3 <br />SUDDEN LOSS LIMIT: 99 <br />TANK <br />RETRY NO: 8 <br />RS -232 END OF MESSAGE <br />TILT <br />PROBE OFFSET <br />0.00 <br />RETRY DELAY: 3 <br />DISABLED <br />0.00 <br />CONFIRMATION REPORT: ON <br />AUTO -DIAL DIAL ALARM - SETUP- - <br />- - - - - - - - <br />SIPHON MANIFOLDED <br />TANKS <br />TU: NONE <br />D 6:SOLVONE MONTHLY TEST <br />LINE MANIFOLDED TANKS <br />- NO ALARM ASSIGNMENTS - <br />TO: NONE <br />AUTO DIAL TIME SETUP: <br />D 6:SOLVONE MONTHLY TEST <br />DIAL ON DATE <br />OCT 30. 2008 <br />DIAL TIME : DISABLED <br />RECEIVER REPORTS: <br />D 7:Solvone ISD Warn <br />DIAL ON DATE <br />OCT 30, 2008 <br />DIAL TIME : DISABLED <br />RECEIVER REPORTS: <br />D 8:Solvone <br />DIAL ON DATE <br />OCT 30, 2008 <br />DIAL TIME : DISABLED <br />RECEIVER REPORTS: <br />D 7:Solvone ISD Warn <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT WARN <br />ALL:DEGRD COLLECT WARN <br />D 8:Solvone <br />IN -TANK ALARMS <br />ALL:LEAK ALARM <br />ALL:HIGH WATER ALARM <br />ALL:OVERFILL ALARM <br />ALL:LOW PRODUCT ALARM <br />ALL:MAX PRODUCT ALARM <br />ALL:GROSS TEST FAIL <br />ALL:PERIODIC TEST FAIL <br />ALL:ANNUAL TEST FAIL <br />ALL:N0 CSLD IDLE TIME <br />ALL:GROSS FAIL LINE TNK <br />LIQUID SENSOR ALMS <br />ALL:FUEL ALARM <br />ALL:SENSOR OUT ALARM <br />ALL:SHORT ALARM <br />ALL:WATER ALARM <br />ALL:WATER OUT ALARM <br />LEAK MIN PERIODIC: 0% <br />0 <br />LEAK MIN ANNUAL 0% <br />0 <br />PERIODIC TEST TYPE <br />STANDARD <br />ANNUAL TEST FAIL <br />ALARM DISABLED <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />GROSS TEST FAIL <br />ALARM DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF <br />TNK TST SIPHON BREAK :OFF <br />DELIVERY DELAY 5 MIN <br />PUMP THRESHOLD lo.00% <br />