My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1103
>
2300 - Underground Storage Tank Program
>
PR0232587
>
COMPLIANCE INFO_2008-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 11:28:16 AM
Creation date
6/3/2020 9:58:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2010
RECORD_ID
PR0232587
PE
2361
FACILITY_ID
FA0004521
FACILITY_NAME
CHEVRON USA #201761*
STREET_NUMBER
1103
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
21935038
CURRENT_STATUS
01
SITE_LOCATION
1103 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232587_1103 S MAIN_2008-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
366
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Work Order: 2255578 <br />F. In d;sssgiag i Sits, i!aICipmemi: (7ttck Ibis box it WIL- {ueging is uscxi nniv 1'or irveniwj cantm':- <br />lJ Cbav:k this box if s!o tank gaugatg or Slit trlufpm— is utswiied <br />This section muss be completed if in -tank gauging equipment is used to perform teak detection monitoring, <br />Com ete the foHawla aitccldi; <br />U Yes <br />u vo' <br />I rias all mina wiring beat iespetted Tor prnper entry and termination, laclac1mg testing forI,TOaad fswlta7 <br />0 Yes <br />❑ No" <br />Were all tank gwging probes visually inspected for damaged residue anbuildup? <br />U Yes <br />O No, <br />Was aaell Loy of system produdl Ievel readings k!ded? <br />❑ Yes <br />❑ No* <br />Was accumLY of system water levet readings tested? <br />Lt Yes <br />g NO' <br />Wcm all probes reinstalled properly? <br />❑ Yes ❑ Nn* Were all items on the equlpmeat manufacturce# maimenance checklist completed? <br />G. Line Leak Detection (LLD): t3 Check this boa irLl Da are not iost�icrt <br />Coal <br />to the <br />checklisk <br />A Yes <br />❑ We <br />For equlpmaat stmt -up ar —usl equipment certification, was a leak simulated to verity LLD performarsce? <br />❑ NIA <br />(Vhe1A all thea q-P1y) Siaailste d leak rate: 16 3 g.p.h.; ❑ 0.1 g p is ; 0 01 g pJL <br />Yes <br />t:i No* <br />Weis all LLDs emflMied operational and a within re s <br />gulafmy requirements. <br />0 Yes <br />4 No* <br />Was the testing appy properly calilxated7 <br />O Yes <br />IV <br />13 No* <br />For modunicul LLDg, dem flats LLD r edriet produet now if it detects a leak? <br />5- NIA <br />Yes <br />I ❑ No* <br />For al Bic LLDs, dog Se Wrbi- RUWmadcaPy sfaa off if Me LID detects a leak? <br />u® Yes u rw- ror etocnonm LLD% lees elm tu:bioe autonialieally shut Off if any portion of the tnoodtoriog system is disabled <br />Cl NIA or discomiecteo <br />0 Yes ❑ No' Far need=le LLDs, dtxs the leabine ily sbsd off, if say potion of the muaitarin <br />❑ NIA or >�la a test? g <br />Yes 0 No' For electronic Ll Dr, baye all accessible wining comiCaUorLs been visually Inspeeh:d? <br />Q NIA <br />lil Yes Cl No* Were all items as the equipment mattufaammes maintenance cheddist ctimpheted? <br />° to the Section Q, below, describe haw sul wbeo umn dencteaeks Waris or will be convete& <br />H. Comments: <br />Page 3 of3 <br />IM <br />Tanknology Inc. 8501 N. MoPac Expressway, Suite 400, Austin, Texas 78759 <br />
The URL can be used to link to this page
Your browser does not support the video tag.