My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1103
>
2300 - Underground Storage Tank Program
>
PR0232587
>
COMPLIANCE INFO_2011-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 11:31:21 AM
Creation date
6/3/2020 9:58:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2014
RECORD_ID
PR0232587
PE
2361
FACILITY_ID
FA0004521
FACILITY_NAME
CHEVRON USA #201761*
STREET_NUMBER
1103
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
21935038
CURRENT_STATUS
01
SITE_LOCATION
1103 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232587_1103 S MAIN_2011-2014.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
457
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ISD SITE ALARMSIN-TANK SETUP <br /> - - - - - - - - - - - - - <br /> ISD STAt-,E I WARN <br /> RS-232 END OF MESSAGE ISD GROSS PRES WARN <br /> DISABLED ISD GROSS PRES FAIL T I :SUPREME <br /> ISD DEGRD PRIES WARN PRODUCT CODE <br /> AUTO DIAL ALARM SETUP ISE) DEGRD PRIES FAIL THERMAL COEFF : .000700 <br /> - - - - - - - - - - - - ISD VAPOR LEAK WARN TANK DIAMETER 92.00 <br /> ISD VAPOR LEAK FAIL TANK PROFILE 4 PTS <br /> D B:tvIAINTENANCE ISD VP PRES WARN FULL VOL 11682 <br /> ISD VP PRIES FAIL 69.0 INCH VOL 9577 <br /> IN-TANK ALARMS ISD VP STATUS WARN 46.0 INCH VOL 5940 <br /> ALL:LEAK ALARM ISD VP STATUS FAIL 23.0 INCH VOL 2272 <br /> ALL;H I(-,'H WATER ALARM MISSING RELAY SETUP <br /> ALL:OVERFILL ALARM MISSING'HOSE SETUP <br /> ALL'LOW PRODUCT ALARM MISSING TANK SETUP FLOAT SIZE: 4.0 IN, <br /> ALL:MAX PRODUCT ALARM MISS VAPOR FLOW MTR <br /> ALL:GROSS TEST FAIL MISS VAPOR PRES SEN WATER WARNING 1 .0 <br /> f4LL:PERIODIC TEST FAIL MISSING Vp INPUT HIGH WATER LIMIT: 2.0 <br /> ALL:ANNUAL TEST FAIL ISD SETUP WARN <br /> ALL:NO CcLD IDLE TIME ISD SETUP FAIL MAX OR LABEL VOL: 11682 <br /> ALL:GROSS FAIL LINE TNI; ISD SENSOR OUT WARN OVERFILL LIMIT 90% <br /> 10513 <br /> LIQUID SENSOR ALI-IS ISD SENSOR OUT FAIL HIGH PRODUCT 95% <br /> ALL:FUEL ALARM PC-ISD FAILURE 11098 <br /> ALL:SENSOR OUT ALARM DELIVERY LIMIT 60' <br /> ALL:SHORT ALARM ISD HOSE ALARMS 70'0 <br /> ALL:WATER ALARM ALL:GROSS COLLECT WARN <br /> ALL:WATER OUT ALARM ALL:GROSS COLLECT FAIL LOW PRODUCT 500 <br /> ALL:HIGH LIQUID ALARM ALL:DEGRD COLLECT WARN LEAK ALARM LIMIT: 99 <br /> ALL:LOW ' IQUIV ALARM ALL:DEGRD COLLECT FAIL SUDDEN LOSS LIMIT: 99 <br /> ALL:LlQtj,l) WARNING ALL:FLOW COLLECT WARN TANK TILT 0.00 <br /> ALL:FLOw COLLECT FAIL PROBE OFFSET 0.00 <br /> PRESSURE LINE LEAK ALL:AIRFLOW MTR SETUP <br /> ALL:GROSS LINE FAIL <br /> ALL:ANNUAL LINE FAIL VAPOR FLW MTR ALMS SIPHON MANIFOLDED TANKS <br /> ALL:PLLD OPEN ALARM ALL:CHK VAPOR FLOW MTR TO: NONE <br /> ALL:PLLD SHUTDOWN ALARM LINE MANIFOLDED TANKS <br /> ALL:PERIODIC LINE FAIL PMC ALARMS TO: NONE <br /> ALL:LOW PRESSURE ALARM VP RUNTIME FAULT <br /> ALL:CONT HANDLE ALM VP EMISSIONS WARN <br /> ALL:FUEL OUT VP EMISSIONS FAIL LEAK MIN PERIODIC: 0% <br /> ALL:LN EQUIP FAULT ALM VP PRESSURE WARN 0 <br /> VP PRESSURE FAIL <br /> VP DUTY CYCLE LJARN LEAK MIN ANNUAL 0% <br /> SMARTSENSOR ALARMS VP DUTY CYCLE FAIL 0 <br /> ALL:COMMUNICATION ALARM PMC SETUP FAIL <br /> ALL:SENSOR FAULT ALARM <br /> ALL:FUEL WARNING PERIODIC TEST TYPE <br /> ALL:FUEL ALARM STANDARD <br /> ALL:WATER WARNING <br /> ALL:WATER ALARM ANNUAL TEST FAIL <br /> ALL:HIGH LIQUID WARNING i ALARM DISABLED <br /> ALL:HIGH LIQUID ALARM <br /> ALL:LOW LIQUID WARNING PERIODIC TEST FAIL <br /> ALL:LOW LIQUID ALARM ALARM DISABLED <br /> ALL:INSTALL ALARM <br /> ALL:SENSOR FAULT WARN GROSS TEST FAIL <br /> ALL:VACUUtl WARNING ALARM DISABLED <br /> ALL:NO VAC70UM ALARM <br /> ANN TEST AVERAGING; OFF <br /> PER TEST AVERAGING: OFF <br /> TANK TEST NOTIFY: OFF <br /> TNK TST CIPHON BREAKOFF <br /> DELIVERY DELAY 5 MIN <br /> PUMP THRESHOLD 10.00% <br />
The URL can be used to link to this page
Your browser does not support the video tag.