Laserfiche WebLink
Appendix VI RECEIVED <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.swrcb.ca.gov.) <br /> MONITORING SYSTEM CERTIFICATION JAN 16 7018 <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7, Health and Safety Code;Chapter 16, Division 3, Title 23, 0OWWORN ENTAL HEALTH <br /> Regulations DEPARTMENT <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: CHEVRON 201761 Bldg. No.: <br /> Site Address: 1103 S.MAIN ST.PERMIT NUMB.N-3315 City: MANTECA Zip: 95337 <br /> Facility Contact Person: MGR-MARIE Contact Phone No.: 209-825-0174 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 1/4/2018 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br /> Tank ID: TI Supreme-SUPREME Tank ID: T2 Regular 2-REGULAR <br /> In-Tank Gauging Probe. Model: mag r%7, In-Tank Gauging Probe. Model: mag <br /> Annular Space or Vault Sensor. Model: 794390-409 17 Annular Space or Vault Sensor. Model: 794390-409 <br /> Piping Sump/Trench Sensor(s). Model: 794380-208 r Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> Fill Sump Sensor(s). Model: 794380-209 rV_ Fill Sump Sensor(s). Model: 794380-209 <br /> r Mechanical Line Leak Detector. Model: r Mechanical Line Leak Detector. Model: <br /> R Electronic Line Leak Detector. Model: Veeder Root PLLD- r Electronic Line Leak Detector. Model: Veeder Root PLLD- <br /> Tank Overfill/High-Level Sensor.Model: flapper r'Tank Overfill/High-Level Sensor.Model: flapper <br /> Other(specify equipment a and model in Section E on Pa e 2). Other(specify equipment a and model in Section E on Pae 2). <br /> Tank ID: T3 Regular 1-REGULAR Tank ID: <br /> In-Tank Gauging Probe. Model: mag r In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: 794390-409 r Annular Space or Vault Sensor, Model: <br /> Piping Sump/Trench Sensor(s). Model: 794380-208 Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: 794380-209 Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> R Electronic Line Leak Detector. Model: Veeder Root PLLD- Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor.Model: flapper r Tank Overfill/High-Level Sensor.Model: <br /> Other(specify equipment a and model in Section E on Pa e 2). Other(specify equipment a and model in Section E on Pacie 2). <br /> Dispenser 1/2 Dispenser 7/8 <br /> ID: ID: <br /> Dispenser Containment Sensor(s).Model: 794380-208 r7l, Dispenser Containment Sensor(s).Model: 794380-208 <br /> Shear Valve(s). 17 Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 3/4 Dispenser 9/10 <br /> ID: ID: <br /> Dispenser Containment Sensor(s).Model: 794380-208 Dispenser Containment Sensor(s).Model: 794380-208 <br /> Shear Valve(s). Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 5/6 Dispenser 11/12 <br /> ID: ID: <br /> - Dispenser Containment Sensor(s).Model: 794380-208 P-0 Dispenser Containment Sensor(s).Model: 794380-208 <br /> Shear Valve(s). rV_ Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply):P System set- <br /> up P Alarm history report <br /> Technician Name(print): Jarrod Cooke Signature: <br /> Certification No.: B35255 License.No.: 743160 Class'A' <br /> Testing Company Name: Tanknology Phone No.: (800)800-4633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 Date of Testing/Servicing: 1/4/2018 <br /> Monitoring System Certification Page 1 of 3 12/07 <br />