My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1989-2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MICHAEL CANLIS
>
7000
>
2300 - Underground Storage Tank Program
>
PR0504967
>
COMPLIANCE INFO_1989-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2023 1:40:41 PM
Creation date
6/3/2020 9:58:45 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1989-2013
RECORD_ID
PR0504967
PE
2361
FACILITY_ID
FA0006440
FACILITY_NAME
SHERIFFS OPERATIONS CTR #2
STREET_NUMBER
7000
Direction
N
STREET_NAME
MICHAEL CANLIS
STREET_TYPE
BLVD
City
FRENCH CAMP
Zip
95231
APN
19305014
CURRENT_STATUS
01
SITE_LOCATION
7000 N MICHAEL CANLIS BLVD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0504967_7000 N MICHAEL CANLIS_1989-2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
571
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OP(�UI/y`�� <br /> SAN JOAQUIN COUNTY • <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> �� 304 East Weber Avenue, 3rd Floor, Stockton, CA 95202-2708 <br /> `P Telephone:(209)468-3420 Fax: (209)464-0138 Web:www.sjgov.org/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility name: Designated Operator: Inspection Date: <br /> fP �jk I - \4,o8l <br /> Faci ity address: UST# <br /> �/ a a n. ' I ' 1 <br /> V" � ,`(/v/r,L✓� �`�/� �' Product �' yw <br /> cility ntact: Title: Phone: i4.(00 <br /> it <br /> 'n Pa e: Piping system: ���� Ov fill prevention: <br /> wtElPressurized 'ruction ❑Gravity echanical ❑Audible/visual <br /> Inspection type: iolations: <br /> Routineonitorin Certification ❑Installation ❑Other: ❑M1-RDetect ❑M2-RPrev ❑M-3 Both <br /> VIOLATION(S) HSC=California Health&Safety Code;CCR=California Code of Regulations V R <br /> # Code Section V <br /> V=Violation;RV=Re eat Violation <br /> 1 HSC 25284 Permit tooperate <br /> 2 CCR 2637 Second containment test performed <br /> 3 CCR 2711 (b)&(c) Current Unified Program Consolidated Forms on file with EHD(Facilityand tank form) <br /> 4 HSC 25292.2 Certification of financial responsibility and CFO letter <br /> 5 CCR 2632(c)(2)(D) Monitoring&response plan is current and filed with the local agency <br /> 6 CCR 2712 i Monitoring&response plan is onsite <br /> 7 CCR 2712 Maintenance&monitoring records (MI) <br /> 8 CCR 2643 d) Daily monitoring of suction piping(pre-January, 1, 1984 <br /> 9 HSC 25292.1 UST system isoperated to prevent unauthorized release <br /> 10 CCR 2632(c)(2) UST monitoring system is present Ml <br /> 11 CCR 2630(d) UST system monitoring equipment is properly located to detect a leak Ml <br /> 12 HSC 25291 (b) UST s stem monitoring equipment isoperational M2 <br /> 13 CCR 2636(f)(1) Continuous monitoring system for underground piping&UDC is present (Mi) <br /> 14 CCR 2631 a Primary containment is product tight <br /> 15 HSC 25291 (a)(2) Secondary containment for UST is tight <br /> 16 CCR 2636(c)(1) All releases in secondary piping flow to a collection sum <br /> 17 HSC 25291 (f) Line leak detector(s)are installed (Ml) <br /> 18 CCR 2635(b)(1) Spill container M2 <br /> 19 CCR 2635(b)(2) Overfill prevention system (M2) <br /> 20 CCR 2636(a) Conventional suction piping shall have continuous monitoring&2°containment <br /> 21 HSC 25291 (e) Water in 2°containment analyzed&properly disposed of <br /> 22 CCR 2650 Recording/reporting of unauthorized releases Ml <br /> 23 CCR 2715 Designated Operator: a)Statement from UST owner; (c-e)Monthly inspection; f)Employee training <br /> 24 CCR 2638 a Annual monitoring certification <br /> 25 CCR 2638(a) Annual line leak detector test (Ml) <br /> 26 HSC 25284.2 Annuals ill containment testing <br /> 27 CCR 2636(f)(4) Annual line tightness test (MI) <br /> 28 CCR 2661 Repair for tank/piping has had tightness test M2 <br /> 29 CCR 2643(e) Biennial tightness test of gravity piping(pre-January 1, 1984) <br /> 30 CCR 2643(d) Triennial line test for conventional suction piping(pre-January1, 1984) M1 <br /> 31 HSC 25292.5 Double walls stem located within 1000'of public well-ELD <br /> 32 CCR 2661 Permit to repair UST system <br /> 33 HSC 25286(a) Permit to alter monitoring system <br /> 34 HSC 25298(b) Permit to temporarily close UST system <br /> 35 HSC 25298(c) Permit to close UST system <br /> 36 HSC 25299(a)(9) Disabling leak detection devices <br /> 37 HSC 25298 a) Illegal abandonment of UST system <br /> 38 Other: <br /> IP O . �9) <br /> UIC <br /> i Septic system: <br /> ❑Serves>_20 people/day <br /> R CEIVED BY: TITL ❑Receives other than sanitary waste <br /> � Other disposal methods: <br /> ❑Dry wells/French Drains <br /> EHD 23-02 <br /> 1/3/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.