My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1989-2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MICHAEL CANLIS
>
7000
>
2300 - Underground Storage Tank Program
>
PR0504967
>
COMPLIANCE INFO_1989-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2023 1:40:41 PM
Creation date
6/3/2020 9:58:45 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1989-2013
RECORD_ID
PR0504967
PE
2361
FACILITY_ID
FA0006440
FACILITY_NAME
SHERIFFS OPERATIONS CTR #2
STREET_NUMBER
7000
Direction
N
STREET_NAME
MICHAEL CANLIS
STREET_TYPE
BLVD
City
FRENCH CAMP
Zip
95231
APN
19305014
CURRENT_STATUS
01
SITE_LOCATION
7000 N MICHAEL CANLIS BLVD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0504967_7000 N MICHAEL CANLIS_1989-2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
571
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB. January 2002 <br />San Joaquin County <br />General Services <br />7000 N. Michael Canlis Blvd. <br />French Camp, CA <br />December 2, 2005 <br />AML <br />� <br />6. PIPING SUMP TESTING <br />Page 4 of 7 <br />Test Method Developed By: <br />Engineer <br />XERXES <br />[ ] Sump Manufacturer [X] Industry Standard [ <br />[ ] Other (Spec) <br />] Professional <br />Test Method Used: <br />[ ] Pressure <br />[ ] Other S eci <br />[ ] Vacuum <br />[X ] Hydrostatic <br />Test E ui ment Used: CALDWELL LEVEL GAUGE Equipment Resolution: 0.0025 <br />NtJi2T, <br />Turbine Sump <br />SO UT'H <br />Turbine Sum <br />Sump Diameter: <br />36 INCH <br />36 INCH <br />Sump Depth: <br />29-1/2 INCH <br />32 INCH <br />Sump Material: <br />FIBERGLASS <br />FIBERGLASS <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />21 INCH <br />22 INCH <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />8 INCH <br />8 INCH <br />Condition of sump prior to testing: <br />DRY <br />DRY <br />Portion of Sump Tested <br />22 INCH <br />23-1/2 INCH <br />Does turbine shut down when sump <br />sensor detects liquid (both product & <br />water)? <br />[ ] YES [ ] NO <br />[ ] NA <br />[ ] YES [ ] NO <br />[X] NA <br />[ ] YES [ ] NO <br />[ INA <br />[ ] YES [ ] NO <br />[ I NA <br />Turbine shutdown response time: <br />N/A <br />Is system programmed for fail-safe <br />shutdown? <br />[ ] YES [ ] NO <br />[ INA <br />[ ] YES [ ] NO <br />[X] NA <br />[ ] YES [ ] NO <br />[ ] NA <br />[ ] YES [ ] NO <br />[ ] NA <br />Was fail-safe verified to be <br />operational? <br />[ ] YES[ ] NO <br />[ ] NA <br />[ ] YES [ ] NO <br />[X] NA <br />[ ] YES [ ] NO <br />[ INA <br />[ ] YES [ ] NO <br />[ ] NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />Test Start <br />10:45 A.M. <br />10:03 A.M. <br />_Time: _ <br />Initial Reading (Rl): <br />22 INCH <br />23-1/2 INCH <br />Test End Time: <br />11:15 A.M. <br />10:33 A.M. <br />Final Reading (Rf): <br />22 INCH <br />23-1/2 INCH <br />Test Duration: <br />30 MINUTES <br />30 MINUTES <br />Chane in Reading Rf-RI)-0- <br />-0- <br />Pass/Fail Threshold or Criteria: <br />PASS <br />PASS <br />Test Result: <br />[X] PASS [ I FAIL <br />[X] PASS [ ] FAIL <br />I I PASS'( I FAIL <br />[ ] PASS [ ] NO <br />Was sensor removed for testing? <br />[X] YES [ ] NO <br />NA <br />[X] YES [ ] NO <br />( INA <br />[ ] YES [ ] NO <br />]NA <br />[ ] YES [ ] NO <br />NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />[X] YES [ ] NO <br />[ ] N/A <br />[X] YES [ ] NO <br />[ I N/A <br />[ ] YES [ ] NO <br />[ ] N/A <br />[ ] YES [ ] NO <br />[ ] NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for tailed tests) <br />1 If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an asterisk (*) is "NO" or <br />"NA", the entire sump must be tested. (SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.