Laserfiche WebLink
SWRCB. January 2002 <br />San Joaquin County <br />General Services <br />7000 N. Michael Canlis Blvd. <br />French Camp, CA <br />December 2, 2005 <br />AML <br />� <br />6. PIPING SUMP TESTING <br />Page 4 of 7 <br />Test Method Developed By: <br />Engineer <br />XERXES <br />[ ] Sump Manufacturer [X] Industry Standard [ <br />[ ] Other (Spec) <br />] Professional <br />Test Method Used: <br />[ ] Pressure <br />[ ] Other S eci <br />[ ] Vacuum <br />[X ] Hydrostatic <br />Test E ui ment Used: CALDWELL LEVEL GAUGE Equipment Resolution: 0.0025 <br />NtJi2T, <br />Turbine Sump <br />SO UT'H <br />Turbine Sum <br />Sump Diameter: <br />36 INCH <br />36 INCH <br />Sump Depth: <br />29-1/2 INCH <br />32 INCH <br />Sump Material: <br />FIBERGLASS <br />FIBERGLASS <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />21 INCH <br />22 INCH <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />8 INCH <br />8 INCH <br />Condition of sump prior to testing: <br />DRY <br />DRY <br />Portion of Sump Tested <br />22 INCH <br />23-1/2 INCH <br />Does turbine shut down when sump <br />sensor detects liquid (both product & <br />water)? <br />[ ] YES [ ] NO <br />[ ] NA <br />[ ] YES [ ] NO <br />[X] NA <br />[ ] YES [ ] NO <br />[ INA <br />[ ] YES [ ] NO <br />[ I NA <br />Turbine shutdown response time: <br />N/A <br />Is system programmed for fail-safe <br />shutdown? <br />[ ] YES [ ] NO <br />[ INA <br />[ ] YES [ ] NO <br />[X] NA <br />[ ] YES [ ] NO <br />[ ] NA <br />[ ] YES [ ] NO <br />[ ] NA <br />Was fail-safe verified to be <br />operational? <br />[ ] YES[ ] NO <br />[ ] NA <br />[ ] YES [ ] NO <br />[X] NA <br />[ ] YES [ ] NO <br />[ INA <br />[ ] YES [ ] NO <br />[ ] NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />Test Start <br />10:45 A.M. <br />10:03 A.M. <br />_Time: _ <br />Initial Reading (Rl): <br />22 INCH <br />23-1/2 INCH <br />Test End Time: <br />11:15 A.M. <br />10:33 A.M. <br />Final Reading (Rf): <br />22 INCH <br />23-1/2 INCH <br />Test Duration: <br />30 MINUTES <br />30 MINUTES <br />Chane in Reading Rf-RI)-0- <br />-0- <br />Pass/Fail Threshold or Criteria: <br />PASS <br />PASS <br />Test Result: <br />[X] PASS [ I FAIL <br />[X] PASS [ ] FAIL <br />I I PASS'( I FAIL <br />[ ] PASS [ ] NO <br />Was sensor removed for testing? <br />[X] YES [ ] NO <br />NA <br />[X] YES [ ] NO <br />( INA <br />[ ] YES [ ] NO <br />]NA <br />[ ] YES [ ] NO <br />NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />[X] YES [ ] NO <br />[ ] N/A <br />[X] YES [ ] NO <br />[ I N/A <br />[ ] YES [ ] NO <br />[ ] N/A <br />[ ] YES [ ] NO <br />[ ] NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for tailed tests) <br />1 If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an asterisk (*) is "NO" or <br />"NA", the entire sump must be tested. (SWRCB LG -160) <br />