My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1989-2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MICHAEL CANLIS
>
7000
>
2300 - Underground Storage Tank Program
>
PR0504967
>
COMPLIANCE INFO_1989-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2023 1:40:41 PM
Creation date
6/3/2020 9:58:45 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1989-2013
RECORD_ID
PR0504967
PE
2361
FACILITY_ID
FA0006440
FACILITY_NAME
SHERIFFS OPERATIONS CTR #2
STREET_NUMBER
7000
Direction
N
STREET_NAME
MICHAEL CANLIS
STREET_TYPE
BLVD
City
FRENCH CAMP
Zip
95231
APN
19305014
CURRENT_STATUS
01
SITE_LOCATION
7000 N MICHAEL CANLIS BLVD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0504967_7000 N MICHAEL CANLIS_1989-2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
571
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C <br />The CFN �,Systern Offers Innovative <br />Modtrtar components allow you to custurn tailor <br />the CFN System. The CFN System is made up of <br />components that can be combined in many ways, <br />You can tailor the system for your particular appli- <br />cation, -.so you never pay for more dean you need. If <br />your needs grow, the CFN System can grow with <br />you, and you can be confident that your original <br />investittent will be preserved for years to come. <br />Create: your own custom commands. You can <br />create custom routines that combine several Site <br />Controller commands into a single command. This <br />allows complicated shift or other procedures to be <br />executed easily by entering only one command. <br />Employees have fewer commands to learn, and the <br />chance of errors is reduced. <br />Store messages or data in gtneral purpose files. <br />You can store manually collected data, such as <br />dipstick readings, in files on the Site Controller. <br />You can also create files for messages, inswictions, <br />or notes to or from employees-, <br />Automatic commands slmplify operation. You <br />can have any Site Controller commands executed <br />automatically at specified tines. You can use this to <br />automatically change prices for -,fay-riight pvicing, or <br />to have reports printed at certain times, for example. <br />Since these tasks are performed automatically, with <br />no intervention required, you don't need to worry <br />that an employee will forget or make an error. <br />Fuel allocation keeps track of prepaid accounts. <br />If you -issue your own cards, the CFN System. allows <br />you to prealtocat` fuel to your. customers. You can <br />have an allocation network under a Network Con- <br />troller or Site Controller It, or or you can set up <br />allocation at each site individually. Allocation units <br />can be dollars or gallons. <br />Fuel limits for every need. The CFN System pru- <br />vides severai types of fuel limits, which can be <br />configured independently. <br />Pump limits set the fill -up amount used for an <br />individual purip. The hourly limit sets the aencunt <br />that one card user can pump iia a specified tune <br />period. <br />If you issue your own cards, you can use limit <br />codes on the cards that restrict access to only certain <br />types of fuel and that limit the amount of fuel that <br />can be accessed in one transaction. <br />Limits can be in either doltars or gallons. <br />The floppy disk drive txpands your horizons. <br />The Site Controller 11 has a floppy disk drive that <br />write& in IBM PC format. This adds inany capabili- <br />ties to the system. For example, you cave write tran- <br />saction data to a floppy disk and then transfer th6 <br />data to a billing or accounting program running iin <br />an IBM PC or compatible. And, data, or even the <br />entire system, can be backed up onto and re8tored <br />from the floppy disk. <br />The CFN Syste nn provides reports for?all your <br />needs. The CFefit System provides several types of <br />reports that allow you to accu.ately monitor' -ales; <br />tank levels, cash drawer amounts, pump,and•fuel` <br />data and other important information. <br />• The sales totals report protides a. summary cif <br />sales by department or type of product and type bf <br />transaction. <br />• The pump totals report prints current prices <br />anis dollar and gallon sales for each pump, or each <br />hose for an MPD. <br />• The cash drawer report prints cash in, `ash <br />out, and balance for the cash drawers fur current' and <br />previous shifts. <br />• The transaction report prints inforr[tationifor <br />each transaction. You can sort transactions: by <br />account number, product, or any oiher.Field; and can <br />specify the transactions to be printed. <br />
The URL can be used to link to this page
Your browser does not support the video tag.