My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1995-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
10842
>
2300 - Underground Storage Tank Program
>
PR0505615
>
COMPLIANCE INFO_1995-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2024 1:45:30 PM
Creation date
6/3/2020 9:58:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995-2011
RECORD_ID
PR0505615
PE
2361
FACILITY_ID
FA0006898
FACILITY_NAME
RAMOS OIL-FRENCH CAMP
STREET_NUMBER
10842
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19333028
CURRENT_STATUS
01
SITE_LOCATION
10842 S HARLAN RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505615_10842 S HARLAN_1995-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
471
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P ---I <br />Alk <br />Figure A: Troubleshooting -,Tuide For <br />Electronic Control <br />Panels <br />Model SBOO11C - Single Circuit Control Panel <br />Test <br />Test Results <br />Conclusion <br />Alarm <br />Alarm <br />Normal <br />Bell <br />Light <br />Light <br />1.0 Symptom: Reservoir Full. <br />ON <br />ON <br />OFF <br />1.1 Check Liquid Media. <br />Remove sensor from reservoir. <br />OFF <br />OFF <br />ON <br />Replace Fluid <br />Insert sensor in container fresh water. <br />ON <br />ON <br />OFF <br />Proceed to Test 1.2 <br />1.2 Check Relay ISRI. <br />ON <br />ON <br />OFF <br />Replace Relay ISRI <br />Jumper terminals G & L on relay ISRI. <br />OFF <br />OFF <br />ON <br />Proceed to Test 1.3 <br />1.3 Check Pushbutton or Sensor. <br />ON <br />ON <br />OFF <br />Replace pushbutton switch <br />Jumper terminals S1 -GI on terminal strap. <br />OFF <br />OFF <br />ON <br />Inspect sensor and wiring <br />for defects <br />2.0 Symptom: Alarm Bell Will Not Silence <br />N/A <br />N/A <br />N/A <br />2.1 Check Silencer Button. <br />N/A <br />N/A <br />N/A <br />Replace pushbutton <br />2.2 Check Relay R2. <br />N/A <br />N/A <br />N/A <br />Replace relay R2 <br />3.0 Symptom: Panel Normal - Pump Cutoff, <br />OFF <br />OFF <br />ON <br />Contacts Open <br />3.1 Check Relay R1. <br />N/A <br />N/A <br />N/A <br />Replace relay Rl <br />Model SB0014C—Four Circuit Control Panel <br />Note: The Normal Light Will Be On Only When All Channels <br />Are Normal <br />Test <br />Test Results <br />Conclusion <br />Alarm <br />Alarm <br />Normal <br />Bell <br />Light <br />Light <br />1.0 Symptom: Reservoir Full <br />ON <br />ON <br />OFF <br />1.1 Check Liquid Media. Remove Sensor from <br />reservoir. Insert sensor in container of fresh <br />OFF <br />OFF <br />ON <br />Replace fluid <br />water. <br />ON <br />ON <br />OFF <br />Proceed to Test 1.2 <br />1.2 Check ISR1 Relay. Jumper sensor terminals <br />corresponding to channel alarming (i.e. <br />OFF <br />OFF <br />ON <br />Check field wiring <br />channel 1 terminal pairs S 1 and G1). <br />ON <br />ON <br />OFF <br />Proceed to Test 1.3 <br />1.3 Verify Switches and Pots Are Set <br />Correctly—Consult factory before <br />Switches and pots set correctly and <br />Replace ISR 1 relay <br />changing settings <br />system alarming. <br />2.0 Symptom: Reservoir Full <br />ON <br />OFF <br />ON <br />2.1 Check ISRI Relay <br />N/A <br />N/A <br />N/A <br />Replace ISR1 relay <br />3.0 Symptom: Reservoir Full <br />ON <br />OFF <br />OFF <br />3.1 Check Warning Light Bulb <br />N/A <br />N/A <br />N/A <br />Replace burned out bulb <br />4.0 Symptom: Reservoir Full <br />OFF <br />ON <br />OFF <br />4.1 Check ISRI Relay <br />N/A <br />N/A <br />N/A <br />Replace ISRI relay <br />5.0 Symptom: Reservoir Overfilled or Empty <br />OFF <br />OFF <br />ON <br />5.1 Push Test Button on Control Panel. <br />ON <br />ON <br />OFF <br />Proceed to Test 5.2 <br />OFF <br />OFF <br />ON <br />Replace ISRI relay <br />5.2 Check Field Wiring. Remove sensor <br />ON <br />ON <br />OFF <br />Replace sensor.* <br />from reservoir and disconnect sensor wiring <br />OFF <br />OFF <br />ON <br />Field wiring shorted.* <br />at junction box. <br />*Note: The monitoring circuit can appear normal if water is present in the junction <br />box or conduit. Water can saturate the splice connections and mask an <br />alarm signal. BE SURE ALL WIRING AND TERMINATIONS ARE PROTECTED FROM MOISTURE. <br />I <br />
The URL can be used to link to this page
Your browser does not support the video tag.