Laserfiche WebLink
FROM :Chris W Papas/David B At on FAX NO. :289 951 5847 c. 06 2006 09:53PM P8 <br /> Praxalr Services, Inc. <br /> = 3755 N. Business Center Drive <br /> Tucson,AZ 85705 <br /> Praxair Services, Inc. Tei: (800)3949929 <br /> Fax:(520)293.1306 <br /> IN SERVICE ENHANCED LEAK DETECTION (ISELD) <br /> TET RESULTS <br /> Client Date: 2=00e Site Info: Job No: 38731 EL <br /> CGRS Wilson Way Chevron <br /> 5444 Dry Creek old. 431 N. Wilson Way <br /> Sacramento, CA 95838 Stockton,CA 95205 <br /> TEST SUMMARY <br /> Praxair Services conducted Enhanced Leak Detection testing on February 20-22,2006.An additional <br /> sample event was also performed on February 25,2006 to evaluate in ground detections that occurred <br /> during original site visit. <br /> 2/20/2006 <br /> Arrived site:7:45 -Site consists of Two(12,000 gallon)Under Ground Storage Tanks and Four dispensers. <br /> The product piping is double wall Smith Fiberglass(2 inch Primary/3 inch Secondary).The vent and vapor <br /> recovery piping is single wall Smith Fiberglass-3 inch Primary. <br /> Upon review,no secondary access was available on the product piping within the dispensers.Attempts were <br /> made to confirm communication without trying to reconfigure the secondary boots-No good method could <br /> be established-It was determined that steps needed to be taken to Install access ports within dispensers- <br /> CGRS will create access.While secondary accesses were being installed, pre-testing continued on the tank <br /> top fittings,sumps and hydro testing of spill buckets.One leak was found and repaired on a nipple within the <br /> 87 turbine sump.Two repairs were also made on the spill bucket drain and swivel adapter.A leak simulation <br /> was introduced into the ground to determine tracer migration and test time frames.All spill bucket passed <br /> the hydro test. CGRS has all but one dispenser equipped with secondary access-OFF SITE:6:45 pm <br /> 2/21/2006 <br /> ON SITE: 8.00 am- Samples collected from vertical probe system confirmed Leak Simulation movement at <br /> adequate concentration and distance in 24 hours. CGRS completed secondary access install in final <br /> dispenser.Tracer was introduced into tanks at 12:00 pm and was detected In fuel samples collected of each <br /> product at target concentrations at the dispensers by 3:45 pm.Samples collected from the secondary of the <br /> product lines showed no detection of tracer and both 87 and 91 product primary lines pass.Samples <br /> collected from tank sumps and Under Dispenser containments(UDCs)show no detection of tracer.All pipe <br /> fittings and connections within these sumps pass. Based on Leak Simulation results,sampling of the probe <br /> system needs to occur 24 hours after the introduction of tracer into the tanks-Will return to complete final <br /> sample event at 12 pm on 2122.OFF SITE:6:45 pm <br /> 2 of 3 38731 EL QA Retest MDC Report-Cert.xis <br />