My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
437
>
2300 - Underground Storage Tank Program
>
PR0506406
>
COMPLIANCE INFO_1996-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/17/2023 3:00:08 PM
Creation date
6/3/2020 9:58:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2008
RECORD_ID
PR0506406
PE
2361
FACILITY_ID
FA0002313
FACILITY_NAME
WILSON WAY CHEVRON
STREET_NUMBER
437
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
15113052
CURRENT_STATUS
01
SITE_LOCATION
437 N WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506406_437 N WILSON_1996-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
469
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br /> D. Results of Testing/Servicing <br /> Software Version Installed: 11.02 <br /> Complete the ist* <br /> [0 <br /> Yes O <br /> Is the audible alarm operational?ON <br /> 0 Yes E]No Is the visual alarm operational? <br /> ❑ Yes No Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> ED Yes No Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their prop2r operation? <br /> [3 Yes No If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? <br /> 0 N/A <br /> M Yes No For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> n N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br /> positive shut down? (Chec*all that apply) 0 SumplTrench Sensors;[I Dispenser Containment Sensors. <br /> Did you confirm p2sitive shut down due to leaks an sensor failure/disconnection? 0 Yes;El No. <br /> Yes No For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no mechanical <br /> [j N/A overfill prevention valve is installed), is the over fill warning alarm visible and audible at the tank fill point(s)and <br /> op2rating pro !tP If yes,at at percent of tank capaci!y does the alarm tri er'? 90% <br /> Yes No Was any monitoring equipment replaced9 If yes, identify specific sensors, probes, or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> CD Yes No Was liquid found inside any secondary containment systems designed as dry systems? (Ch ec*all that app <br /> Product;[]Water 0. If n,describe causes in Section E,below. <br /> EY <br /> I:No was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> No is all monitoring equipment operational per manufacturer's specifications? <br /> In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> Veeder Root stand alone sensors are used for the dispenser containment monitoring. The sensors shut down the <br /> Dispensers only and will shutdown the dispenser upon disconnection also. <br /> Site does not have an audible/visual overfill alarm at the tank pad. However,the fill sumps are monitored and ball floats <br /> have been installed. <br /> The annular sensor in the unleaded tank was inaccessible;the sensor could not be tested. <br /> Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.