Laserfiche WebLink
0 0 <br /> D. Results of Testing/Servicing <br /> Software Version Installed: 11.02 <br /> Complete the ist* <br /> [0 <br /> Yes O <br /> Is the audible alarm operational?ON <br /> 0 Yes E]No Is the visual alarm operational? <br /> ❑ Yes No Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> ED Yes No Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their prop2r operation? <br /> [3 Yes No If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? <br /> 0 N/A <br /> M Yes No For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> n N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br /> positive shut down? (Chec*all that apply) 0 SumplTrench Sensors;[I Dispenser Containment Sensors. <br /> Did you confirm p2sitive shut down due to leaks an sensor failure/disconnection? 0 Yes;El No. <br /> Yes No For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no mechanical <br /> [j N/A overfill prevention valve is installed), is the over fill warning alarm visible and audible at the tank fill point(s)and <br /> op2rating pro !tP If yes,at at percent of tank capaci!y does the alarm tri er'? 90% <br /> Yes No Was any monitoring equipment replaced9 If yes, identify specific sensors, probes, or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> CD Yes No Was liquid found inside any secondary containment systems designed as dry systems? (Ch ec*all that app <br /> Product;[]Water 0. If n,describe causes in Section E,below. <br /> EY <br /> I:No was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> No is all monitoring equipment operational per manufacturer's specifications? <br /> In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> Veeder Root stand alone sensors are used for the dispenser containment monitoring. The sensors shut down the <br /> Dispensers only and will shutdown the dispenser upon disconnection also. <br /> Site does not have an audible/visual overfill alarm at the tank pad. However,the fill sumps are monitored and ball floats <br /> have been installed. <br /> The annular sensor in the unleaded tank was inaccessible;the sensor could not be tested. <br /> Page 2 of 3 <br />